Battery Power Line II STERRAD Systems Sterilization Guide

2 Pages

STERRAD SYSTEMS STERILIZATION GUIDE ®  For Battery Power Line II (BPL II) Li-ion battery (530.630)  1  2  • Before cleaning, remove all instruments and attachments from the power tool. Remove the battery casing from the handpiece and then remove the battery from the battery casing. • 	Inspect battery for cracks or damage. •  	 Wipe off battery with a clean, soft, and lint-free cloth dampened with deionized or purified water.  Wipe off battery with a clean, soft and lint-free cloth dampened with alcohol based disinfectant for thirty (30) seconds. A disinfectant that is VAH listed, EPA registered or locally recognized is recommended. This step has to be repeated two (2) additional times using a new clean, soft and lint-free cloth dampened with disinfectant each time.  Preparation Before Cleaning  Note: If the battery is contaminated, spray disinfectant on an absorbent cloth and wipe clean. Take care not to spray the contacts or touch both contacts at the same time with the damp cloth due to danger of short circuiting.  Cleaning  3  4  •	Place the battery into the Universal Battery Charger II* (05.001.204). • Charge the battery. When the green LED illuminates, the battery is fully charged. • Upon completion of charging the battery, wipe the battery with disinfectant prior to returning to use.  The batteries can either be wrapped or peel pouched. Follow manufacturer’s instruction for wrapping that is compatible with the STERRAD® Systems.  Charging  Wrapping and Labeling  * Universal Battery Charger II with firmware version 14.0 or higher is required to charge BPL II Li-ion batteries.  5  6   • 	 Process the battery in the STERRAD Systems following the manufacturer’s instructions. • 	 Li-Ion battery has been validated with the following:  • Battery can be used immediately or stored in accordance with hospital’s procedures. • Rotate stock and re-charge unused batteries, as necessary.  Sterilize  Storage and Use  STERRAD Systems and Cycle (US)  STERRAD Systems and Cycle (outside US)  STERRAD 50  STERRAD 50  Warning:  STERRAD 200  STERRAD 200 Short cycle  STERRAD 100S  STERRAD 100S Short cycle  STERRAD NX Standard cycle  STERRAD NX Standard cycle  x	 Never expose batteries to temperature over 60ºC/140ºF. The maximum exposure time at 60ºC/140ºF is 72 hours. • Do not dismantle, open, or shred batteries.  STERRAD 100NX Standard cycle  STERRAD 100NX Standard cycle  For more information on the Universal Battery Charger II, please refer to the related User’s Manual.
File Type: PDF
File Size: 112 KB
File Name: Synthes - DSUS-PWT-0116-0152 - Battery Power Line II STERRAD Systems Sterilization Guide - 2016-05.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions