Teleflex Medical

5" DRILL BIT SET FULLY LOADED WITH CASE

Insert, PTD, Generic, Sterility Reproc

14 Pages

en  INSTRUMENT DESCRIPTION The following instructions are for metal reusable general surgical instruments that are characterized by the following design features (examples): • • •  Accessible surfaces Accessible apertures Ring handle style instruments accessible surfaces  Note: instruments do not require manual manipulation to gain access to all surfaces  •  Ring handle box-lock style instruments with or without ratchets accessible surfaces  •  Forcep (tweezer) style instruments  accessible surfaces  •  Sliding shaft instruments that can be taken apart (dismountable) sliding shaft  take-apart (dismountable)  For additional information or guidance on Cleaning and Sterilization instructions, contact your Teleflex Sales Representative or Teleflex Customer Service. INDICATIONS FOR USE Teleflex instruments are designed to perform a specific function, such as cutting, grasping, clamping, dissecting, probing, retracting, draining, aspirating and suturing. Instruments are for use by, or as directed by, a trained medical professional. Instruments should be used only for the purpose for which they are designed. The proper technique for the use of the instrument is the responsibility of the medical professional. PREPARATION AT POINT OF USE Directly after use, remove coarse contamination from the instrument and keep the instrument moist for transit to the processing site. Prior to cleaning and sterilization do not use any fixing agents or hot water >104°F (>40°C) since this may lead to the fixation of residue and can interfere with the cleaning process. TRANSPORTATION During the transportation of the instrument to the processing site, store contaminated instrument securely in a closed container to avoid damage to the instrument and/or contamination of the environment. PREPARATION FOR REPROCESSING Where applicable, instruments must be disassembled and/or opened for cleaning and sterilization. Open ring handled instruments so that ratchets are not engaged. Failure to properly clean and sterilize the instrument could lead to contaminated instruments being placed back into circulation.  CLEANING, DISINFECTION AND DRYING INSTRUCTIONS Automatic Processing Instructions Manual Processing Instructions For For Use with Alkaline or Enzymatic Use with Enzymatic Detergents Detergents PRE-CLEANING PRE-CLEANING • Soak the instrument in lukewarm • Soak the instrument in lukewarm tap water for a minimum time of tap water for a minimum time of 5 minutes. 5 minutes. • Disassemble the instrument (if • Disassemble the instrument (if applicable). applicable). • Brush under lukewarm tap water • Brush under lukewarm tap water with a soft brush until all visible with a soft-bristled brush until all residues are removed. visible residues are removed. CLEANING CLEANING • Place the opened instrument in a • Place the instrument in an perforated basket on the slide-in ultrasound bath at 104°F (40°C) tray and start the cleaning process. with a 0.5% enzymatic detergent. • Pre-rinse for 2 minutes with cold • Sonicate for 10 minutes (minimum). water. • Remove the instrument and • Empty. flush with lukewarm tap water for • Pre-rinse for 3 minutes with cold approximately 15 seconds while water. simultaneously brushing with a soft• Empty. bristled brush. • Wash for 5 minutes at 131°F (55°C) Note: The preparation of with a 0.5% alkaline detergent concentration, temperature and or at 113°F (45°C) with a application time of the cleaning 0.8% enzymatic detergent. agent must be according to the • Empty. instructions for use provided by the • Neutralize for 3 minutes with cold detergent manufacturer. Detergents water. must be approved for use with metal • Empty. reusable general surgical instruments. • Rinse for 2 minutes with cold water. Examples of detergents used in • Empty. validations: Enzymatic Detergent: Note: The preparation of Cidezyme/Enzol. concentration, temperature and application time of the cleaning agent must be according to the instructions for use provided by the detergent manufacturer. Detergents must be approved for use with metal reusable general surgical instruments. Examples of detergents used in validations: Enzymatic Detergent: Cidezyme/Enzol; Alkaline Detergent: Neodisher Mediclean. DRYING Dry the outside of the instruments using the drying cycle of the cleaning equipment. If necessary, the instruments can be dried by hand with a lint-free cloth. Compressed, filtered air can be used for instruments with lumens. DISINFECTION Teleflex does not provide disinfection instructions due to the sterility instructions provided.  DRYING Dry instruments with a lint-free cloth. Compressed, filtered air can be used for instruments with lumens.  DISINFECTION Teleflex does not provide disinfection instructions due to the sterility instructions provided.
File Type: PDF
File Size: 1.86 MB
File Name: Teleflex Medical - L05521 - Insert, PTD, Generic, Sterility Reproc - 2020-04 - R02.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions