Teleflex Medical

522225 With Strong Extension

Pilling Bronchoscopes, Esophagoscopes, Laryngoscopes, Mediastinoscopes and Subglottiscopes Instructions for Use

14 Pages

en  INSTRUMENT DESCRIPTION The following instructions are for metal, reusable Pilling Bronchoscopes, Esophagoscopes, Laryngoscopes, Mediastinoscopes and Subglottiscopes:  PREPARATION FOR REPROCESSING Where applicable, the instrument must be disassembled and/or opened for cleaning and sterilization. Failure to properly clean and sterilize the instrument could lead to contaminated instruments being placed back into circulation. CLEANING, DISINFECTION AND DRYING INSTRUCTIONS  Bronchoscope  Esophagoscope  Laryngoscope  Mediastinoscope  Subglottiscope For additional information or guidance on Cleaning and Sterilization instructions, contact your Teleflex Sales Representative or Teleflex Customer Service. INDICATIONS FOR USE Instruments are for use by, or as directed by, a trained medical professional. Instruments should be used only for the purpose for which they are designed. The proper surgical technique for the use of the instrument is the responsibility of the medical professional. PREPARATION AT POINT OF USE Directly after use, remove coarse contamination from the instrument and keep the instrument moist for transit to the processing site. Prior to cleaning and sterilization do not use any fixing agents or hot water >104°F (>40°C) since this may lead to the fixation of residue and can have a negative influence on the cleaning process. TRANSPORTATION During the transportation of the instrument to the processing site, store contaminated instrument securely in a closed container to avoid damage to the instrument and/or contamination of the environment.  Automatic Processing Instructions For Use with Alkaline or Enzymatic Detergents ENZYMATIC PRE-CLEANING • If possible, disassemble the handles. • Disassemble light carriers and window plugs (if applicable) from scopes. • Soak the scopes, light carriers and window plugs (if applicable) in lukewarm tap water for a minimum time of 5 minutes. • Brush the scopes, light carriers, and window plugs (if applicable) under lukewarm tap water until no residuals are visible. • Care must be taken to reach all areas. The housing of the rigid optics is brushed using an adequate brush.  Manual Processing Instructions For Use with Enzymatic Detergents  CLEANING • If possible, disassemble the handles. • Disassemble light carriers and window plugs (if applicable) from scopes. • Soak the scopes, light carriers and window plugs (if applicable) in lukewarm tap water for a minimum time of 5 minutes. • Brush the scopes, light carriers, and window plugs (if applicable) under lukewarm tap water until no residuals are visible. • Care must be taken to reach all areas. The housing of the rigid optics is brushed using an adequate brush. • The scopes, light carriers and CLEANING window plugs (if applicable) are • Place the opened instrument in a then soaked in a bath with 0.8% perforated basket on the slide-in solution of enzymatic cleaner for a tray and start the cleaning process. minimum time of 10 minutes. • Pre-wash for 2 minutes with • After soaking, the scopes, light cold water. carriers and window plugs (if • Empty. applicable) are brushed again and • Wash for 5 minutes at 113°F (45°C) thoroughly rinsed under lukewarm with a 0.8% enzymatic detergent. tap water. • Empty. Note: The preparation of • Neutralize for 3 minutes with concentration, temperature and cold water. application time of the cleaning agent • Empty. must be according to the instructions • Rinse for 2 minutes with cold water. for use provided by the manufacturer. • Empty. Examples of detergents used during Note: The preparation of validations: Enzymatic Detergent: concentration, temperature and application time of the cleaning agent Cidezyme/Enzol. must be according to the instructions for use provided by the manufacturer. Examples of detergents used during validations: Enzymatic Detergent: Cidezyme/Enzol.
File Type: PDF
File Size: 458 KB
File Name: Teleflex Medical - Pilling - L000612 - Pilling Bronchoscopes, Esophagoscopes, Laryngoscopes, Mediastinoscopes and Subglottiscopes Instructions for Use - 2022-03 - R00.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions