Teleflex Medical

ADSN BIPOLAR FCP INSLTD SMTH JW 1.0MM TP

Pilling Laparoscopes and Accessories IFU

4 Pages

Indications for Use PILLING® Laparoscopes and Accessories are intended to be used by qualified physicians to provide access, illumination and visualization of internal structures and for manipulating soft tissue (grasping, cutting, coagulating, dissecting, and suturing) in a wide variety of diagnostic and therapeutic laparoscopic/urologic closed and minimally invasive procedures. Caution: Federal U.S. laws restrict this device to sale by or on the order of a physician only. Special safety precautions should be observed when using electrosurgical instruments. Electrosurgical instruments can pose a significant shock, burn or explosion hazard if used improperly, incorrectly or carelessly. Caution: Please refer to the labelling and user manual for the electrosurgical generator for additional information on contraindications on electrosurgical or laparoscopic use. Cautions & Warnings: Avoid touching or grounding electrosurgical instruments to non-insulated instruments, scopes, trocar sleeves, etc. All persons using such devices should be knowledgeable in the use and handling of laparoscopic instruments, laparoscopes, coagulation equipment, their accessories and other related equipment. Test all instruments, accessories and equipment prior to each use. Written standard operating procedures for cleaning, sterilization, storage, inspection and maintenance of the instruments, accessories and equipment are recommended. To avoid tissue carbonation, the operating voltage of the HF generator must not exceed 650 peak voltage (Vp) for all monopolar electrodes. Do not use electrosurgical instruments on patients with pacemakers. Do not use in presence of flammable liquids or anaesthetics. Electrosurgical generators used with these devices are designed to cause destruction of tissue and are inherently dangerous if operated improperly. Follow all safety precautions and instructions supplied by the manufacturer of the electrosurgical generator. The electrode tip must always be in full view before activating power. Apply power only when electrode tip is in full contact with the tissue selected for coagulation. Electrode tip must not come in contact with the laparoscope or other metal instruments during use. Failure to observe these cautions and contraindications may result in injury, malfunction or other unanticipated occurrences or events for the operator, staff and/or the patient.  L06061 R02  Page 1 of 4
File Type: PDF
File Size: 726 KB
File Name: Teleflex Medical - L06061 R02 Final - Pilling Laparoscopes and Accessories IFU - 2020-04 - R02.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions