Quick Start Guide
4 Pages
Preview
Page 1
Thermo Scientific EPD TruDose Quick Start Guide
External Features Label Recess • Place for color coding populations using COTS “dots”
Ultra Bright LED • Visible from the top and the front
Infrared Interface • Provides communication to/from the EPD
Select Button • Enables users to move through the menus and select functions
Detector Marking • Indicates EPD type: βɣ – Beta-Gamma ɣ – Gamma ɳɣ – Neutron-Gamma
LCD Display • Shows parameters and/or functionality as selected by the buttons
Sounder
• Audible indicator of an alarm
Navigate Button • Dual button design simplifies navigation, reduces training required to operate
Beta Window
• Covers the β detector (BG version-only)
Battery Compartment • Front load, secured with screws in the back
For further operating instructions and Thermo Scientific™ EPD TruDose™ details, please refer to the User Manual.
Insert/Replace Battery
Wearing The EPD TruDose should be worn under the direction of the Health Physicist. For most operating conditions, it is recommended that the EPD TruDose be worn on the outside of any protective clothing. Note that the buttons should be facing outwards.
1. Unscrew battery hatch
2. Use battery hatch recess to open cover
Attached to belt
3. Insert the battery
Worn in or on pocket
Note battery polarity markings
4. Replace battery hatch and reinsert screws.
Select and Navigate Buttons Clip Assembly
Select • Used to select a given display or action a command.
EPD Label
Navigate • Used to navigate from one display to another.
EPD TruDose Quick Start Guide
Display Menu Navigate Structure Power Off
Clear Dose
Bluetooth On/Off
Audible/Visual Alarms On/Off
Hp10
Dose
Rate
Dose Alarm
Dose Warning
Dose Rate Alarm
Dose Rate Warning
Total Dose (∑)
Peak Dose Rate (Pk)
Hp07
Dose
Rate
Dose Alarm
Dose Warning
Dose Rate Alarm
Dose Rate Warning
Total Dose
Peak Dose Rate
Assignment
Wearer Name
Wearer ID#
Task Name
Task#
Time Remaining
Time Remaining
% of total Hp10 dose received
Diagnostic
Counts
Version
Cal Due Date
Run Confirmation Test
Operations
•
Alarm Demo
Indicates Screen can be pinned; could be enabled as a Quick Access display
• Key Actions (e.g. Clear Dose, Turn Off, run conf test) require confirmation to execute (can’t be done accidentally)
To Turn ON/OFF
Measurement Display Layout
1. To Turn On:
Numeric Area
Units Area Measurement Identity Area
Example Dose Display
256.3µSv Hp10 Example Rate Display
242
mrem/h
Hp10
EPD TruDose Quick Start Guide
Chrome Right
Chrome Left
LCD Display Layout
a. At the
OFF
b. At the
screen, double press screen, press
Note: On display is used to prompt the user to turn the unit on. If no button is pressed during the 2 second timeout, the display will revert to the Off Mode Display.
2. To Turn Off: a. At the
24.6µSvHp10 screen, double press
b. At the
Menu
screen, press
c. At the
Operations
screen, press
d. At the
screen, press
e. At the
screen, press
f. The unit will now be off.
OFF
Typical Dose Display Screens Hp10
Menu Display
3.3µSv Hp10
Dose
0.1µSv/hHp10
Dose Rate
150.0µSvHp10
Dose Alarm
100.0µSvHp10
Dose Warning
75.0µSv/h Hp10
Dose Rate Alarm
50.0µSv/h Hp10
Dose Rate Warning
3.6µSvHp10
Total Dose
0.6µSv/h Pk Hp10
Peak Dose Rate
EPD TruDose G
EPD TruDose BG
Note: The EPD TruDose G is similar except the Beta window is replaced with a plastic dome.
EPD TruDose NG
Find out more at thermofisher.com/epdtrudose © 2021 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. RB 2933189 0521 v02