CLEANING AND STERILIZATION PROTOCOL Tiger Large Cannulated Headless Screw System CLEANING  Recommended Manual Cleaning Instructions:  1. Rinse with tap water to remove gross soil 2. Inject water (60mL) into cannulation to remove gross soil 3. Prepare enzymatic detergent (Enzol®) at manufacturer recommendation (1oz/gal) using lukewarm tap water and fully immerse parts 4. Use a soft bristled brush (Spectrum M16 or equivalent) and appropriately sized lumen brush to brush all surfaces 5. Use syringe to inject detergent (60mL) into cannulation 6. Allow articles to dwell in detergent bath for 1 minute Recommended Automatic Cleaning Instructions: 7. Remove parts from bath and rinse using reverse 1. Rinse with tap water to remove gross soil osmosis/deionized (RO/DI) water 2. Inject water (60mL) into cannulation to remove gross soil 8. Fill syringe with RO/DI water (60mL) and flush part 3. Prepare enzymatic detergent (Enzol®) at manufacturer cannulation, where applicable recommendation (1oz/gal) using lukewarm tap water 9. Allow parts to air dry. A clean lint-free cloth may be used and fully immerse parts to aid in drying 4. Use a soft bristled brush (Spectrum M16 or equivalent) 10. Visibly inspect for remaining soil on part and appropriately sized lumen brush to brush all surfaces NON-STERILE PRODUCT STERILIZATION 5. Use syringe to inject detergent (60mL) into cannulation 6. Allow articles to dwell in detergent bath for 1 minute Trilliant Surgical Implant Systems can be packaged non7. Remove parts from bath and rinse using reverse sterile and therefore must be sterilized prior to surgical use. osmosis/deionized (RO/DI) water Use of the sterilizer shall comply with the manufacturer’s 8. Fill syringe with RO/DI water (60mL) and flush part user instructions. The user facility must clean and disinfect cannulation, where applicable instruments prior to sterilization per standard hospital 9. Transfer parts into automated washer (STERIS® procedures. Non-sterile devices are sterilizable by steam Reliance Genfore) for processing using the following sterilization (autoclaving). The following parameters should parameters: be followed: Non-sterile products must be carefully cleaned prior to sterilization. Trained personnel must perform cleaning and mechanical inspection prior to sterilization. Compliance is required with the equipment manufacturer’s user instructions (manual and/or machine cleaning, ultrasound treatment, etc.) and recommendations for chemical detergents. Trilliant Surgical recommends the following cleaning and sterilization instructions:  Phase  Recirculation Temperature Time  Detergent Type and Concentration  Sterilization Method  Pre-Vacuum Steam  Condition  Wrapped*  Wrapped*  N/A  Temperature  270°F (132°C)  270°F (132°C)  Time  4 minutes  30 minutes  Dry Time  Recommended 50 minutes**  Recommended 70 minutes**  Pre-wash 1  02:00  Cold tap water  Enzyme Wash  02:00  Hot tap water  Enzol® 1 oz/gal  Wash 1  02:00  65.5°C  Prolystica® 2X Neutral 1/8 oz/gal  Rinse 1  01:00  Hot tap water  N/A  Drying  15:00  90°C  N/A  Gravity Steam  *The system shall be packaged for sterilization by double wrapping in standard central supply wrap (i.e. Bio-Shield® Sterilization Wrap). **Trilliant Surgical has validated the recommended sterilization cycle and dry time for trays. The dry time varies due to load configuration, wrapping method, and material.  10. Visibly inspect for remaining soil on part  This document is controlled by Trilliant Surgical. When downloaded, printed, and/or copied, this document becomes UNCONTROLLED and users should always check Trilliant Surgical’s website, www.trilliantsurgical.com, to ensure they have the latest version.  Trilliant Surgical 727 North Shepherd Drive Suite 100 | Houston, TX 77007 Phone: 800-495-2919 | Fax: 877-778-3864 | www.trilliantsurgical.com  Page 1 of 1 900-06-012 Rev D
File Type: PDF
File Size: 130 KB
File Name: Trilliant Surgical - DJO Surgical - 900-06-012 - Tiger Large Cannulated Headless Screw System Cleaning and Sterilization Protocol - Rev D.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions