VAPOTHERM

Precision Flow PLUS Quick Reference Guide Rev A

Quick Reference Guide

2 Pages

DISPOSABLE PATIENT CIRCUIT • • • • • • •  Attach High or Low Flow Vapor Transfer Cartridge to Disposable Water Path Attach patient delivery tube to Disposable Water Path Open door and install Disposable Water Path into docking station so there is no gap between bottom of the Disposable Water Path and the Docking Station Floor Hang sterile water bag Wipe water spike with alcohol pad and insert into sterile water bag Allow a minimum of 200ml of water to fill into the Disposable Patient Circuit . Precision Flow® Plus is ready for start up  Q U I CK  START UP AND ADJUSTING PARAMETERS • • • • • • •  Install oxygen sensor. Replace sensor annually. Install gas inlet filters on back with filter bowls vertical (glass side down). Replace gas inlet filters every six months. Attach air & O₂ hoses. Plug in power cord. Rotate the blue Setting Control Knob to illuminate display Press in Setting Control Knob to select the parameter and rotate to adjust the value Press and release (do not hold) the Run/Standby button once to start. A GREEN light indicates RUN mode (AMBER light indicates STANDBY mode, No Flow) Green light will stop flashing once temperature is reached  CONNECT TO PATIENT • • • •  The flashing green LED becomes steady when the set variables are reached. Place the cannula on the delivery tube After cannula is attached, it is ready to be placed on patient The unit should not be placed in Standby mode for extended periods of time. For pauses in therapy, remove cannula from the patient, set the parameters to the lowest available setting and clamp the inlet/spike tube when not in use. To reinitiate therapy, before cannula is placed on patient, place the unit into RUN mode to clear accumulated condensate.  INTERNAL BATTERY BACK-UP • • • • •  indicative of charge) level)  Blocked tube  General fault  • • • • •  Alarm mute LED  22 Industrial Drive Exeter, NH 03833 T: 603-658-0011 USA  Technical Support T: +1 (603) 658-5121 International 855 557 8276 Domestic ts@vtherm.com  May be patented. www.vapotherm.com/patents 3100955 Rev. A  High Flow Vapor Transfer Cartridge  Vapor Transfer Cartridge fault (Low flow & High flow)  Gas supply fault  Press and hold the Run/Standby button for 2 seconds. Unit will enter Standby mode (No Flow), indicated by the AMBER light. Clamp the water inlet tube and disconnect it by pulling out the spike. Open the door, remove the Disposable Patient Circuit (includes delivery tube & cartridge) by sliding it upwards out of the docking station Discard all disposables according to hospital guidelines. Disconnect unit from AC power. Wipe down with any of the following: 70-90% Isopropyl Alcohol, 2% (maximum) chlorine cleaning solution, 6% (maximum) Hydrogen Peroxide cleaning solution, CaviWipesTM, or Sani-ClothTM AF3 Germicidal.  VAPOTHERM, INC.  Disposable Water Path faulty or absent Low Flow Vapor Transfer Cartridge  SHUT DOWN •  G U I D E Battery low or charging (not  Water out  The back-up battery is designed for temporary use only, when AC power to the unit has been interrupted. The unit will enter into battery mode and will maintain flow and oxygen percentage for at least 15 minutes. The battery icon will flash. Replace battery every two years. Battery recharges in two hours.  R E FE R E N CE  RMS–UK Ltd. 28 Trinity Road Nailsea, North Somerset BS48 4NU United Kingdom  Alarm mute button  Setting Control Knob  Run/Stop Status LED Run/Standby button  This guide provides you with basic instructions on how to set up and operate the Precision Flow® Plus. Before operating the Vapotherm Precision Flow® Plus, please review the Operating Instruction Manual which can be found at our website www.vapotherm.com and on the USB drive provided in the Start-Up Kit.
File Type: PDF
File Size: 807 KB
File Name: VAPOTHERM - 3100955 - Precision Flow PLUS Quick Reference Guide Rev A.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions