WelchAllyn

Halogen Exam Light III Models 48xx series Instructions Rev E

Instructions

2 Pages

WARNING: Do not perform neonatal trans-illumination without the use of the #48210 neonatal trans-illuminator (with U.V. filter). Do not remove the focusing sleeve from the light pipe and use the light pipe for trans-illumination. Severe burns may result.  Halogen Exam Light III  Halogen Exam Light III with Fiberoptic Light Pipe Model #’s - 48700, 48722, 48724, 48726, 48728  Halogen Exam Light III with Fiberoptic Light Cable Model #’s - 48780, 48782, 48784, 48786, 48788  General practices to minimize risk of harm to the skin from optical radiation hazards include: minimizing illumination intensity at the tissue examination site, minimizing exposure times, and taking additional precautions when skin sensitivity has been altered through tissue trauma or the use of anesthesia. General good practices to minimize risk of harm to the eyes from optical radiation hazards include: avoid looking at bright light sources and their reflections, and protect eyes where normal pupil sizes and aversion responses are not present.  Halogen Exam Light III with Neonate Light Pipe Model #’s - 48760, 48762, 48764, 48766, 48768  Halogen Exam Light III Light Box with Power Cord Model #’s - 48740, 48742, 48744, 48746, 48748  INTRODUCTION Thank you for purchasing the Welch Allyn Halogen Exam Light III. We believe that it is the highest quality product of its kind available in the world today. By following the simple guidelines found within this manual, you should be rewarded with years of dependable, trouble free performance. If you have any questions or concerns please feel free to contact our customer or technical service departments at (800) 535-6663 during normal business hours. Welch Allyn remains committed to providing innovative, quality diagnostic products for healthcare professionals. Call us at (800) 535-6663 to request a full line product catalog or visit us at our Web Site, www.WelchAllyn.com.  SYMBOL DESCRIPTIONS  There are no user serviceable/replaceable parts other than lamp and fuses. Please refer any other service to qualified and authorized service centers.  MOUNTING  Accessories  Fiberoptic Light Pipe (Shown with Focusing Sleeve) Model 48200  Fiberoptic Light Cable (Shown with Focusing Sleeve)  1.  Using the mounting plate as a template, mark drilling holes as needed (depending on your wall type).  2.  Dry Wall, Paneling, Plywood or Plaster (1/8 inch (.3 cm) to 5/8 inch (1.6 cm) thick) - drill four (4) 3/8 inch (1cm) holes, insert hollow metal wall anchor assembly.  3.  Concrete Block - drill four (4) 3/16 inch (.5 cm) holes, insert plastic anchors. Use #8 x 1/2 inch screws to secure.  4.  Metal Panel or Plywood walls greater than 5/8 inch (1.60 cm) thick drill four (4) 1/8 inch (.3 cm) holes. Use #8 x 1 inch screws to secure.  5.  Once holes are drilled, install the mounting plate with the appropriate screws. Completely tighten the screw so there is no gap between the screw head and the mounting plate.  6.  Mount the Light Box to the plate by inserting the pins on the back of the light box into the slots on the mounting plate. Let the light box drop down to position the pins into the narrow portion of the mounting slots .  7.  To secure the Light Box to the plate, insert two (2) .50” (1.27cm) screws through the bottom of the mounting plate and tighten into the bottom of the Light Box using a phillips head screwdriver .  Model 48220  Focusing Sleeve Model 48605  Neonatal Transilluminator Light Box, Power Cord and Wall Mount Model 48740 (Domestic) Model 48742 (Europe) Model 48744 (UK) Model 48746 (Australia) Model 48748 (Japan)  Model 48210 The optional neonatal Light Pipe/ transilluminator is used to assist in the diagnosis of pneumothorax, to locate blood vessels, etc. This transilluminator incorporates a permanently attached ultraviolet filter that minimizes the transmission of ultraviolet light. The standard Fiberoptic Light Pipe or Fiberoptic Light Cable should NOT be used for transillumination of neonates.  Fiberoptic Light Pipe (shown with focusing sleeve) Model 48200 (Included only with Model #’s 48700, 48722, 48724, 48726, and 48728)  To secure the Light Box to the mounting plate, insert two (2) .50” (1.27 cm) screws through the bottom of the mounting plate and tighten into the bottom of the Light Box using a Phillips head screwdriver.  Wall Mount Choose appropriate mounting location. The length of the light pipe is 4 feet totally extended (fiberoptic light cable is 7.5 feet). When choosing a mounting location, keep these dimensions in mind in addition to accounting for the actual application the light will be used for and what portion of the examination table will need to be accessed.  COMPONENTS Standard  5.  Use one of the following three mounting options in order to ensure proper operation of the light box.  NOTE: Some tables require additional reinforcement of the mounting bracket to support the mounted light. In this case, we recommend using a 1” (2.5 cm) thick piece of plywood. When employing this reinforcement to the bracket, please follow instructions 6 - 11 below. 6.  Trace the outline of the mounting plate and mark the hole locations on a 3/4 inch (1.9cm) thick piece of plywood.  7.  Cut the piece of wood to the outline size and drill four .25 inch (.64cm) holes.  8.  Using the mounting plate as a template, mark the hole locations on the table and drill (4) .25 inch (.64 cm) holes in the table.  9.  Using four 8-32 x 2 inch (5.08 cm) screws with lock washers and nuts, install the block of wood and mounting plate to the table as shown in the diagram.  10.  Mount the light box to the plate by inserting the pins on the back of the light box into the slots on the mounting plate. Let the light box drop down to position the pins into the narrow portion of the mounting slots.  11.  To secure the Light Box to the mounting plate, insert two (2) .50” (1.27cm) screws through the bottom of the mounting plate and tighten into the bottom of the Light Box using a phillips head screwdriver.      Table Mount Bracket Model 48859  Attention: Consult user’s manual for additional information. Warning: Risk of fire. Replace fuses as marked. Caution: High Temperatures Fiberoptic Light Cable (shown with focusing sleeve) Caution: High Intensity Light  WARNINGS & CAUTIONS WARNING: The user of this equipment should be thoroughly trained in the medical procedures appropriate to the utilization of this instrumentation. Furthermore, time should be taken to read and understand the instructions contained within this manual prior to use of this product. Instructions for other equipment used in conjunction with the Exam Light III (for example: suction machines, electrosurgical generators, etc.) should also be read and understood. Failure to understand the operating requirements for this product may result in injury to yourself, the patient and/or may damage the instrument. CAUTION: Electric Shock Hazard - Remove power cord from electrical outlet and allow lamp to cool before replacing (Welch Allyn lamp # 04200). DANGER: Risk of explosion if used in the presence of flammable anesthetics. CAUTION: Federal Law restricts this device to sale by or on the order of a physician. CAUTION: Illumination is intense - Do not stare at the light source in operation. May be harmful to eyes. CAUTION: Use the examination light in its intended working range of 12 to 24 inches. Exposures at closer distances may be harmful to skin.  Model 48220 (Included only with Model #’s 48780, 48782, 48784, 48786, and 48788)  Neonatal Transilluminator Model 48210 (Included only with Model #’s 48760, 48762, 48764, 48766, and 48768)  Mobile Stand Model 48850  Disposable Sheaths    NOTE: Some exam table manufacturers supply mounting hardware for installation of the Exam Light III. Check with your table supplier for availability.  Model 52640  Disposable Sheath Dispenser Focusing Sleeve    Model 52641  Model 48605  (Included only with Model #’s 48700, 48722, 48724, 48726, 48728, 48780, 48782, 48784, 48786, and 48788)  WARNING: It is the responsibility of the health facility of user to ensure that the mounting bracket is securely anchored to the wall or table, or that the mobile stand is securely assembled, and the exam light is securely fastened to the bracket or stand as directed below. Give consideration to the load that is placed upon the mount. Welch Allyn, Inc. does not accept responsibility for any installation, nor for damage or injury arising from the installation of any mounting bracket or mobile stand, regardless of the type of fasteners and technique used. 1.  35W Halogen Replacement Lamp Model 04200  Determine the side of the table that is most optimal for mounting the light. Consider the location of the nearest power outlet and patient traffic.  NOTE: Verify that the top of the mounting bracket is at least 10 inches (25.4 cm) below the table top cushion and that the mounting position will not interfere with the operation of the table. 2.  Using the mounting plate as a template, mark the hole locations on the table and drill four (4) .25 inch (.64 cm) holes in the table.  3.  Using four 8-32 screws with lock washers and nuts, install the mounting plate to the table as shown in the diagram.  4.  Mount the light box to the plate by inserting the pins on the back of the light box into the slots on the mounting plate. Let the light box drop down to position the pins into the narrow portion of the mounting slots.
File Type: PDF
File Size: 1.56 MB
File Name: WelchAllyn - Halogen Exam Light III Models 48xx series Instructions Rev E.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions