ThermoScan Charging Station PRO 6000 Directions for Use Rev B
Directions for Use
20 Pages
Preview
Page 1
ThermoScan
®
Charging station Directions for use
PRO 6000 1 Charging station
English
ThermoScan
®
PRO 6000 Charging station This manual applies to
901009 Accessory, Thermometry
Manufactured by: Welch Allyn, Inc. 4341 State Street Road Skaneateles Falls, NY 13153 USA
107983 (CD) DIR 80025533 Rev B Revision Date: 2019-10
Welch Allyn Limited Navan business Park Dublin road, Navan, County Meath Republic of Ireland C15 AW22 For information about any Welch Allyn product, contact: Welch Allyn Technical Support: www.welchallyn.com/support visit locations: www.welchallyn.com/about/company/locations.htm Replacement parts For a complete list of parts, go to www.welchallyn.com For patent information, visit www.welchallyn.com/patents
Use only Hillrom probe covers
© 2019 All rights reserved. Made in Mexico This product is manufactured under license to the ‘Braun’ trademark. ‘Braun’ is a registered trademark of Braun GmbH, Kronberg, Germany. ThermoScan® is a registered trademark owned by Helen of Troy Limited.
1
English 1. Braun Thermoscan® PRO 6000 Charging station
2 10
1
9
8 4
3 5
7
6
2
English 2. Package components Braun ThermoScan® PRO 6000 Charging station CD containing Directions for use, Welch Allyn Service Tool software (available via internet link) and Service Tool installation guide (available via internet link) 1 Rechargeable battery pack (NiMH) 1 Set of interchangeable wall plug(s) 1 Wall adapter and USB cable
3. Product description 1 Storage space for sleeve of 200 Braun probe covers 2 Braun ThermoScan® PRO 6000 Ear thermometer in its cradle 3 Charging indicator 4 Power indicator 5 USB cable 6 Wall adapter 7 Interchangeable plug (available in 4 different configurations) Model number
Plug configuration
PRO6000BSNA / 06000‑100
North America / China plug
PRO6000BSEU / 06000‑125
EU & UK plugs
PRO6000BSC / 06000‑575
North America / China, EU & UK plugs
PRO6000BSAU / 06000‑150
Australia plug
8 USB connection adapter 9 USB retaining clip 10 Wall mounting holes
3
English
SAVE THESE INSTRUCTIONS The charging station for the Braun Thermoscan® PRO 6000 Ear thermometer, a clinical grade thermometer, provides charging and security function, as well as storage for the thermometer and the probe cover dispensers. Before use, read the directions for use carefully.
4. Warnings and precautions To reduce the risk of electric shock: WARNING Do not reach for charging station that has fallen into water. Unplug immediately. WARNING Do not place, store or charge the charging station where it can fall or be pulled into a tub or sink. Do not place or drop in water or other liquid. WARNING Unplug this charging station before cleaning. WARNING The charging station is provided with a low-voltage wall adaptor (Medical Wall Mount Adapter, type TMW7‑5‑IPW). Therefore you must not exchange or manipulate any part of it. Otherwise there is risk of electric shock. WARNING Professional use only. CAUTION In order to charge the thermometer, the charging station must only be used with the rechargeable battery pack supplied with this unit. To reduce the risk of burns, fire, electric shock, or injury to persons: WARNING The charging station must not be operated within 1.5 m (4.92 feet) of the patient’s vicinity. CAUTION Use this appliance only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. WARNING Do not modify this equipment without authorization of manufacturer. CAUTION The appliance should never be exposed to temperatures of less than -20°C (-4°F) and more than +50°C (122°F). Keep the appliance and cord dry at all times. Do not handle with wet hands. Do not store in a damp environment. To avoid damage do not wind the cord around the appliance. It is important to check the cord for damage periodically (every 3 months) particularly at each end where the cord enters the plug. WARNING Never operate this appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or if it has been dropped into water. Return the appliance to a service center for examination and repair. CAUTION Keep the cord away from heated surfaces. WARNING Never drop or insert any object into any opening. CAUTION Always attach plug to appliance first, then to outlet. CAUTION This device complies with current required standards for electromagnetic interference and should not present a problem to other equipment nor is it affected by other devices. As a precaution, avoid using this device in close proximity to other equipment. WARNING Do not position the device so that it is difficult to operate or disconnect the device (Plug).
4
English 5. Setup 5.1 Battery installation The charging station is supplied with 1 rechargeable battery pack. To make use of the charging function place the rechargeable battery pack in the battery compartment of the thermometer. The battery pack may not be charged when delivered. CAUTION Please charge the device for 3 hours in the charging station before use. See 5.2 Connecting and 5.4 Charging the thermometer.
1
Open battery door by sliding spring latch to the right using your finger or a pointed object such as a pen. While holding the latch in the open position, grasp the battery door and remove it.
2
Insert rechargeable battery pack into battery compartment with battery label facing outward.
3
Snap the battery door back into place and ensure the latch returns to original latched position.
can
®
moS
Ther
This product contains batteries and recyclable electronic waste. To protect the environment, do not dispose of it in the trash, but take it to appropriate local collection points according to national or local regulations. CAUTION Do not disassemble, short circuit or dispose of in fire. Do not mix with different battery types.
5
English 5.2 Connecting
1
Connect the USB cable to the back of the charging station (1a) and feed the cable through the retaining clip (1b).
2
Select the appropriate interchangeable plug for your country and region (if more than one plug is supplied).
3
Connect the plug to the wall adapter.
4
Plug USB cable into wall adaptor.
5
Plug the entire assembly into the electrical outlet.
6
A green light will illuminate, indicating the charging station is ready for use.
1a
1b
6
English 5.3 Mounting instructions (optional) The charging station can be mounted to a wall or set up on a flat surface. The charging station should be mounted to the wall after completing step 3 of section 5.2 Connecting. The following materials will be needed for mounting: • 2 Philips head #8 pan head screws (included) • 2 Flush mount dry wall anchors (included) • Ruler (not included) • Phillips head screwdriver −#2 drive (not included)
To mount to wall:
1
Ensure the USB cable is disconnected from the electrical outlet but still attached to the charging station. The USB connection on the charging station will not be accessible after mounting.
2
Locate the screws and dry wall anchors included with charging station.
3
Locate mounting holes on back of charging station.
4
Using the provided drywall anchors and screws affix the charging station to the wall or other secure location.
64.0 mm mm 64.0 (apx.2.52") (apx. 2.52")
Note: If affixing the charging station to a surface other than drywall, please use fasteners appropriate to the surface.
5.4 Charging the thermometer
1
Place the thermometer with rechargeable battery pack installed into the thermometer cradle (1a). Place the thermometer in cradle into the charging station (1b).
1a
1b
7
English 2
The thermometer will produce an audible beep.
3
The charging indicator on the charging station will illuminate amber.
4
The battery charge status will be displayed on the thermometer LCD.
The charging indicator on the charging station will change to green when the thermometer is fully charged (approximately 3 hrs. if battery is empty). It is not possible to overcharge the batteries. It is recommended that the thermometer is stored in the charging station when not in use to maintain a full charge. Please note, even with a full battery the charging station may take up to 5 minutes to recognize the full battery level. If this occurs the charging indicator will be amber upon installation of the thermometer in the charging station and then turn to green once the fully charged battery is recognized. If you notice the charging station indicates a full charge (green charging indicator) but the thermometer LCD does not indicate a full charge it maybe a result of the charging station or batteries being overly warm. It is recommended that you remove the charge station to a cooler environment. If the charging indicator is not illuminated one of the following may have occurred: –– Alkaline batteries (non rechargeable) are installed –– Thermometer / charging station are not connected correctly to an electrical source –– Thermometer is not correctly installed in the charging station
8
6. Security function The Braun Thermoscan® PRO 6000 Ear thermometer is equipped with a security function which requires returning the thermometer to the charging station within a pre-selected time. If this time is exceeded, the thermometer will be locked. The security feature can be set through the Service Tool up to 12 hours / 720 minutes. When leaving the factory, the security function of the Braun Thermoscan® PRO 6000 Ear thermometer is turned off. Security is only available via the use of the Welch Allyn Service Tool software and requires the charging station or any compatible Welch Allyn Vital Signs device to initiate. The security function may be used with rechargeable or alkaline batteries. See 6.2 Settings to access this feature and change the settings.
6.1 How it works
1
When the security function is enabled, an unlocked icon is displayed next to the battery indicator during normal use to show that the security function is active.
2
When the thermometer is within 60 minutes of the time limit a countdown clock showing the number of minutes remaining is shown next to the unlocked icon.
3
……
…
……
…
At 5 minutes prior to expiration the thermometer will begin to beep once per minute and the unlocked icon will flash to indicate imminent locking of the thermometer.
9
English
…
English
… …
4
Upon expiration of the time limit, the unlocked icon and countdown timer will be replaced with the locked icon and the thermometer will beep once every 5 minutes to indicate locked state. Any button pressed in the locked state will result in an error beep and no other response from the thermometer. The thermometer cannot be used in the locked state.
5
Unlock the thermometer by returning it to the charging station.
6
The thermometer will produce an audible beep and the backlight will illuminate for 5 seconds.
7
The time limit will be reset and the thermometer will return to the unlocked state for normal operation. When unlock state has been achieved, the thermometer will beep and the display will return.
… 1a
1b
10
English 8
Charging the thermometer with security function enabled: If rechargeable batteries are installed the amber light on the charging station will illuminate indicating charging has resumed and the battery icon will appear on the thermometer display. Although security function will operate, if alkaline batteries (non rechargeable) are installed in the thermometer the amber light will not illuminate on the charging station, the battery icon will not appear on the thermometer display and the batteries will not charge.
6.2 Security function settings The charging station or compatible Welch Allyn Vital Signs device can be used with the Welch Allyn Service Tool to modify settings on the thermometer. The Welch Allyn Service Tool software is required to modify the thermometers configuration. A charging station and rechargeable batteries or compatible Welch Allyn Device is required to connect to the PC running the Welch Allyn Service Tool. Follow the instructions to access Braun Thermoscan® PRO 6000 Ear thermometer advanced settings using the Welch Allyn Service Tool.
1
Dock the Braun Thermoscan® PRO 6000 Ear thermometer in the charging station.
2
The recommended action is to use the USB cable that connects to the wall adapter-unplug it from the wall adapter and plug it into your computer.
11
English 3
a. Launch the Welch Allyn Service Tool. b. If the startup screen with the “Add new features” and “Service” button appears click “Service”. c. Log in as ADMIN with no password or use any account you previously created. Note: If the log on prompt does not appear click the Log on button. You must be logged on to access the configuration dialog.
4
Click the Braun thermometer from the device list to highlight and click the select button.
5
The Device tab opens.
6
Click the Configure tab to the right of the device information tab.
12
English 7
Click the Change button in the current settings box. The configuration settings dialog box opens.
8
To select the security function, click the drop down menu and click the desired time or Off to disable. Once the desired settings are selected click the Save button to send the settings to the Braun thermometer and close the box. To close the box without changing the settings click the Cancel button.
6.3 Service tools For more information on the Service Tool and Service Tool installation guide go to www.welchallyn.com and download the service tool found under the Services & Support Tab/Service Centers/Download service tool.
13
English 7. Maintenance & service 7.1 Cleaning
Caution CAUTION Do not use bleach solutions of any kind when cleaning metal electrical contacts. They will damage the contacts. CAUTION Clean the contacts only with with 70% isopropyl alcohol. Allow contacts to dry for 1 minute. As needed, clean the charging station with a slightly damp cloth or cleaning wipe with a 70% isopropyl or ethyl alcohol solution, 10% chlorine bleach solution, non-staining cleaning solutions (e. g. Metrex CaviWipes™, PDI Sani-Coth®) or hydrogen peroxide (e. g. Virox and Oxivir) cleaning solutions. Approved cleaning solutions Family
Solution or brand
Charge station body
Contacts
Chlorine and chlorine compounds
10% Chlorine bleach solution
Yes
No
Quaternary ammonium compounds
CaviWipes™ Clinell® Universal Wipes SaniCloth Metrex
Yes
No
Hydrogen peroxide
Virox Oxivir
Yes
No
Alcohol
70% isopropyl or ethyl alcohol
Yes
Yes
Additional cleaning agents may be periodically evaluated for compatibility. If your cleaning agent is not listed, contact Welch Allyn to determine if additional cleaning agents are approved for use. Note: If any cleaning agent other than isopropyl or ethyl alcohol comes into contact with the contacts immediately wipe dry. Then clean the contacts with isopropyl or ethyl alcohol.
14
English Caution CAUTION Do not use abrasive cleaning agents. WARNING Unplug the charging station before performing any maintenance or service. WARNING Do not submerge the charging station in water or any other liquid. CAUTION Wipes should be moist, not saturated. Excess liquid may cause damage to the charging station. CAUTION To clean the thermometer and cradle follow the Braun Thermoscan® PRO 6000 Ear thermometer cleaning instructions as specified in the PRO 6000 Directions for use, maintenance & service. WARNING It is important to check the cord for damage periodically (every 3 months) particularly at each end where the cord enters the plug.
7.2 Storage instructions Store thermometer and probe covers in a dry location (the thermometer is not protected against ingress of water), free from dust and contamination and away from direct sunlight. The ambient temperature at the storage location should remain fairly constant and within the range of -20 to 50°C (-4 to 122°F).
15
English 8. Specifications Operating ambient temperature range: 10–40 °C (50–104 °F)
External medically certified power supply ratings: Output Voltage: Output Current: Input Voltage: Input Current: Input Frequency:
5Vdc 1A 100-240VAC 0.3A 50-60Hz
Long term storage ranges Storage temperature: Storage humidity: Electrical rating: Rechargeable battery warranty: Battery capacity: Rechargeable battery type: Charging station dimensions: Charging station weight:
-20 to 50°C (-4 to 122°F) 0 to 85% non condensing 750 mAh 3 years Up to 700 temperature measurements per full charge / 3 V customized dual battery pack (NiMH) 3.51" H × 4.08" D × 6.02" W (89.2 mm H × 103.7 mm D × 153.0 mm W) 5.3 oz / 150 g
CAUTION Do not use this device in the presence of electromagnetic or other interference outside the normal range specified in IEC 60601‑1‑2.
W E L C H A L LY N A U S T R A L I A P T Y LT D UNIT 5 38 SOUTH STREET R Y D A L M E R E , N S W 2 116 AUSTRALIA
16
English Standards and compliance This device conforms to the following Safety and Performance Standards: This product conforms to the provisions of the EC directive 93/42/EEC (Medical Device Directive). ANSI/AAMI STD ES60601‑1, UL STD 60601‑1, CAN/CSA STD C22.2 No. 60601.1, IEC 60601‑1 and EN 60601‑1; 2nd and 3.1 Editions. Medical electrical equipment- Part 1: General requirements for basic safety and essential performance BS EN 60601-1-2:2015, IEC 60601‑1‑2:2014 Medical electrical equipment-Part 1–2: General requirements for basic safety and essential performance-Collateral standard: Electromagnetic compatibility-Requirements and test IEC/EN 62366-1: 2015 (IEC 60601‑1‑6:2010+A1: 2013) Medical devices-Application of usability engineering to medical devices ISO 14971:2012 Medical devices-Application of risk management to medical devices MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC. For detailed description of EMC requirements please contact an authorized local Service Centre. Portable and mobile RF communications equipment can affect MEDICAL ELECTRICAL EQUIPMENT Internally powered ME equipment. Continuous operation. Not protected against ingress of water. IPX0
17
English
Symbol definitions: Type BF Applied Part Caution The caution statements in this manual identify conditions or practices that could result in damage to the equipment or other property, or loss of data. Warning The warning statements in this manual identify conditions or practices that could lead to illness, injury, or death. Warning symbols will appear with a grey background in a black and white document. Class II Equipment
Separate collection of Electrical and Electronic Equipment. Do not dispose as unsorted municipal waste.
Consult instructions for use.
Power indicator Charging indicator
-25 –20°C -13
50°C 55 122°F 131
Storage temperature
–4°F
85
Storage humidity
0
18
English
9. Limited three year manufacturer’s warranty For Model Braun Thermoscan® PRO 6000 Charging station Welch Allyn (an affiliate of Hill-Rom®) warrants the product to be free of defects in material and workmanship and to perform in accordance with manufacturer’s specifications for the period of three years from the date of purchase from Welch Allyn or its authorized distributors or agents. The date of purchase is: 1) the invoiced ship date if the device was purchased directly from Welch Allyn, 2) the date specified during product registration, or 3) the date of purchase of the product from a Welch Allyn authorized distributor as documented from a receipt from said distributor, whichever date is earlier. This warranty does not cover damage caused by 1) handling during shipping, 2) use or maintenance contrary to labeled instructions, 3) alteration or repair by anyone not authorized by Welch Allyn, or 4) accidents. This warranty does not cover batteries, damage to the probe window, or damage to the instrument caused by misuse, negligence or accident, and extends to only to the first purchaser of the product. Replaced units under warranty will have the remainder of the replaced unit’s warranty length. Additionally, this warranty becomes void if the thermometer is operated with anything other than genuine Hillrom™ probe covers.
19