ZOLL
Base Power Charger Operators Manual Rev B
Operators Manual
26 Pages
Preview
Page 1
The revision level for this document is shown on the front cover. 1x1 ZOLL, PowerCharger , QuickCharge, and AutoTest are trademarks of ZOLL Medical Corporation. © 2002 by ZOLL Medical Corporation. All rights reserved. Service Policy Warranty In North America: Consult your purchasing agreement for terms and conditions associated with your warranty. Outside of North America, consult the ZOLL authorized representative. In order to maintain this warranty, the instructions and procedures contained in this guide must be strictly followed. For additional information, please call the ZOLL Technical Service Department 1-800-348-9011 in North America. (International customers: 781-229-0020).
Table of Contents 6HFWLRQ *HQHUDO,QIRUPDWLRQ 3URGXFW'HVFULSWLRQ +RZWR8VH7KLV0DQXDO 6HFWLRQ'HVFULSWLRQV 0DQXDO8SGDWHV 8QSDFNLQJ :DUQLQJV *HQHUDO 3DWLHQW6DIHW &DXWLRQ 6SHFLILFDWLRQV 'LVSODV &RQWUROV =2//%DWWHULHV 6PEROV8VHGRQWKH(TXLSPHQW 6HUYLFH
6HFWLRQ 2SHUDWLRQ 2SHUDWLQJ&RQWUROVDQG,QGLFDWRUV 6HWXS %DWWHU&KDUJLQJ &DXWLRQ 0DQXDO%DWWHU7HVWLQJ3URFHGXUH 4XLFN5HIHUHQFH&KDUWIRU%DVH3RZHU&KDUJHU [ZLWK$XWR7HVW 4XLFN5HIHUHQFH&KDUWIRU%DVH3RZHU&KDUJHU [ZLWK4XLFN&KDUJH
6HFWLRQ 0DLQWHQDQFHDQG7URXEOHVKRRWLQJ ,QVSHFWLRQ &OHDQLQJ 2SHUDWLRQDO&KHFNV 7URXEOHVKRRWLQJ
6HFWLRQ %DWWHU0DQDJHPHQW =2//%DWWHU3DFNV %DWWHU/LIH([SHFWDQF /RZ%DWWHU0HVVDJH %DWWHU'LVSRVDO
6HFWLRQ (0&6SHFLILFDWLRQV *XLGDQFHDQG0DQXIDFWXUHU¶V'HFODUDWLRQ(OHFWURPDJQHWLF(PLVVLRQV *XLGDQFHDQG0DQXIDFWXUHU¶V'HFODUDWLRQ(OHFWURPDJQHWLF,PPXQLW *XLGDQFHDQG0DQXIDFWXUHU¶V'HFODUDWLRQ(OHFWURPDJQHWLF,PPXQLW 1RQ/LIH 6XSSRUWLQJ(TXLSPHQW
i
Section 1 General Information 3URGXFW'HVFULSWLRQ The ZOLL Base PowerCharger 1x1 (with QuickCharge or AutoTest) is a battery charger and testing system designed for management of Battery Packs used in ZOLL Medical Corporation resuscitation devices. The ZOLL Base PowerCharger 1x1 can be configured in either the AutoTest or QuickCharge mode. This configuration is performed by ZOLL Medical Corporation prior to device shipment. The Base PowerCharger1x1 is clearly labeled AutoTest or QuickCharge on the charger label directly beneath the product name.
$XWR7HVW The ZOLL Base PowerCharger 1x1 with AutoTest automatically tests battery capacity with each battery recharge (when the battery has been depleted for 10 minutes or more) and illuminates the BATT. READY indicator when the battery is fully charged. With AutoTest, the full charging cycle is complete in eight (8) hours or less for the PD4410/Smart Battery and fifteen (15) hours or less for the XL Smart Battery. The AutoTest feature virtually eliminates the need to periodically test battery capacity since this test is performed each time a battery is recharged. See the M Series Operator's Manual for battery run time information.
4XLFN&KDUJH The ZOLL Base PowerCharger 1x1 with QuickCharge illuminates the BATT. READY indicator when the battery is fully charged. The full charging cycle is complete in four (4) hours or less for the PD 4410/Smart Battery and eight (8) hours or less for the XL Smart Battery . The QuickCharge version provides no information regarding battery capacity because it does not test capacity with each recharge. The ZOLL Base PowerCharger 1x1 with QuickCharge relies on the user to manually initiate the battery test cycle at recommended intervals (see Manual Battery Testing Procedure) in order to confirm adequate battery capacity.
+RZWR8VH7KLV0DQXDO This manual provides information necessary for the use and care of the Base PowerCharger 1x1 and ZOLL Batteries. A thorough understanding of this information is required for proper charging and maintenance of ZOLL Batteries. Reliable operation of ZOLL Medical Corporation resuscitation devices requires proper battery care.
6HFWLRQ'HVFULSWLRQV This manual is divided into five sections. The operator should read each section carefully.
6HFWLRQ*HQHUDO,QIRUPDWLRQ Provides Cautions, Warnings and a general product overview of the Base PowerCharger 1x1. Includes detailed product specifications and important ZOLL service information.
6HFWLRQ2SHUDWLRQ Describes the function of all controls and indicator lights of the Base PowerCharger 1x1. Discusses proper setup of the Base PowerCharger 1x1 and provides charging and testing instructions.
6HFWLRQ0DLQWHQDQFHDQG7URXEOHVKRRWLQJ This section describes several routine checks to assure proper unit operation. It includes cleaning and maintenance instructions and troubleshooting guides intended for use by nontechnical personnel.
6HFWLRQ%DWWHU0DQDJHPHQW Provides information for determining your particular battery requirements and program implementation steps to setup a comprehensive, effective and safe battery management program.
6HFWLRQ(0&6SHFLILFDWLRQV Provides detailed product information pertaining to EMC Emissions and Immunity testing.
1
ZOLL Base PowerCharger 1x1 Operator’s Manual
0DQXDO8SGDWHV If you purchased your product more than three years ago, contact ZOLL to determine whether updates to your documentation are available. For information relating to recent manual updates, contact ZOLL Medical Corporation's Technical Service Department at 1-781-2290020.
8QSDFNLQJ Carefully inspect each container for damage. If the shipping container or cushion material is damaged, it should be kept until the contents have been checked for mechanical and electrical integrity. If the contents are incomplete, if there is mechanical damage, or if the instrument does not pass its electrical self-test, customers should call ZOLL's Technical Service Department at 1-781-229-0020. The following items are packed in the Base PowerCharger 1x1 shipping container:
• Base PowerCharger 1x1 • Base PowerCharger 1x1 AC Power Cord • 1 Base PowerCharger 1x1 Operator’s Guide
2
General Information
Warnings and Cautions :DUQLQJV *HQHUDO • The Base PowerCharger 1x1 has been tested against
•
• •
•
•
interference from radio frequency emissions typical of two-way radios used in emergency service/public safety activities. Users of the Base PowerCharger 1x1 should refer to Section 5 to determine recommended operation distances from RF transmission equipment. Use only the AC power line cord supplied with the device. Failure to use the proper line cord could result in excess leakage currents and reduced safety. Do not disassemble the Base PowerCharger 1x1. A shock hazard exists. Refer all problems to ZOLL Technical Service. Follow all recommended maintenance instructions. If a problem occurs, obtain service immediately. Do not use the Base PowerCharger 1x1 until the unit has been inspected by the appropriate personnel. Do not place anything on top of or beneath the Base PowerCharger 1x1, such as blankets or cloths. Doing so may block the vents on the unit, preventing proper dissipation of heat during operation. Do not use adjacent to or stacked with other equipment. If adjacent or stacked use is necessary the Base PowerCharger 1x1 should be observed to verify normal operation. Do not sterilize the Base PowerCharger 1x1.
• • Do not use alcohol or ketones (MEK, acetone, etc.) • •
on the Base PowerCharger 1x1. Always wait until the Base PowerCharger 1x1 has completed its charge cycle before removing batteries. Repeated use of partially charged batteries will reduce their capacity and operating life.
• Do not use a battery unless the BATT. READY •
indicator is lit and the FAULT light is off. Failure to do so may result in the use of a fully depleted battery. Do not install batteries into Monitor/Defibrillators when storage may exceed 90 days. Battery damage may occur.
2SHUDWRU6DIHW
• Do not operate the Base PowerCharger
•
1x1 in the presence of flammable agents (such as gasoline), oxygen-rich atmospheres, nitrous oxide, or flammable anesthetics. Using the device near the site of a gasoline spill may cause an explosion. Do not immerse or set the Base 3RZHU&KDUJHU [ in liquid. Using the device near or within puddles of water may present a shock hazard to the operator, patient, and nearby personnel.
3DWLHQW6DIHW • Do not mount the device directly above the patient. Locate the Base 3RZHU&KDUJHU [ and ZOLL resuscitation devices where they cannot harm the patient if they fall.
&DXWLRQ • When a fully charged battery is placed into the Base PowerCharger 1x1 with the AutoTest, the AutoTest will NOT activate and the BATT. READY indicator will illuminate within a few minutes after inserting the battery into the charger. Since the AutoTest sequence is not performed, it is possible to have a shorter battery run time than expected.
3
ZOLL Base PowerCharger 1x1 Operator’s Manual
6SHFLILFDWLRQV
'LVSODV
%DVH3RZHU&KDUJHU [ *HQHUDO
POWER
Illuminates when Base PowerCharger 1x1 is plugged into live AC mains.
CHARGER ON
Indicates battery is being charged.
BATT. READY
Illuminates when the charge cycle is complete.
FAULT
Illuminates when battery capacity test or battery compartment test fails
TESTING
Illuminates when either a battery test or a battery compartment test is in progress.
Size
8.2 cm H x 15.8 cm W x 31.8 cm L (3.2 in. x 6.2 in. x 12.5 in.)
Weight
2.1 kg (4.5lbs) without batteries.
Equipment Classification
Class 1, No Patient Applied Parts, Ordinary, Portable, Continuous Operation
Input Rating
100-120 VAC, 50/60 Hz, 340mA. (or) 220-240 VAC, 50/60 Hz, 170mA.
Safety Standards
Designed to meet or exceed: EN60601-1 Medical Electrical Equipment Part 1: General Requirements for Safety. Designed to meet or exceed: IEC 60601-1-2 Medical Electrical Equipment Part 1-2: General Requirements for Safety. Collateral standard: Electromagnetic Compatibility Requirements and Tests.
Base PowerCharger1x1 with AutoTest only: Illuminates with the CHARGER ON light during AutoTest and recharge of the battery.
&RQWUROV TEST Button
Automatically charges, discharges and recharges the battery.
=2//%DWWHULHV
UL2601-1 Standard for Medical Electrical Equipment. Part 1: General Requirements for Safety with respect to Electrical Shock, Fire and Mechanical Hazards only.
Type
Rechargeable , sealed lead acid. ZOLL Battery Pack PD 4410 ZOLL Smart Battery ZOLL XL Smart Battery
(UL Classification mark associated with 100-120 VAC input only.)
Weight
PD 4410/Smart Battery: 1 kg (2.2 lbs) XL Smart Battery: 1.68 kg (3.7 lbs)
Size
PD 4410/Smart Batttery: 4 cm H x 7 cm W x 18.9 cm L (1.58 in. x 2.78 in. x 7.44 in.)
Recharge Time QuickCharge Four hours or less for total recharge of fully depleted battery for PD 4410/Smart Battery. Eight hours or less for XL Smart Battery. AutoTest
Temperature
Humidity
Eight hours or less for AutoTest and total recharge of battery for PD 4410/Smart Battery. Fifteen hours or less for XL Smart Battery. 5 °C to 40 °C(operating) 15°C to 35°C (optimal battery charging) -40°C to 70°C (storage and transportation) 5% to 95% (relative humidity - non condensing).
External Fuses (2 ) 400 mA/250V Time Delay fuses for 100-120 VAC input. (2) 200mAL/250V, Type T fuses for 220-240 VAC input.
4
Illuminates TESTING indicator light and initiates battery test cycle or battery compartment test.
XL Smart Battery: 9.4 cm H x 7 cm W x 20 cm L (3.7 in. x 2.78 in. x 7.9 in.) Capacity
PD 4410/Smart Batttery: 2.5 Amp Hour rating for new batteries XL Smart Battery: 4.5 Amp Hour rating for new batteries
Nominal Battery 2.0 V/cell; 5 cells. Voltage Temperature
0 °C to 50 °C(operating) 15°C to 35°C (optimal battery charging) -40°C to 70°C (storage and transportation)
Humidity
5% to 95% (relative humidity - non condensing).
Capacity Test
At a minimum, test batteries every three months. Refer to ZOLL’s Battery Management Program brochure.
General Information
6PEROV8VHGRQWKH(TXLSPHQW Any or all of the following symbols may be used in this manual or on this equ equipment: Attention Refer to manual for more information Protective (earth) ground terminal
Alternating current
Conformité Européenne Complies with the medical device directive 93/42/EEC
6HUYLFH Should the Base PowerCharger 1x1 require service, return it in its orginal container, to the nearest authorized ZOLL Medical Corporation service center.
5
ZOLL Base PowerCharger 1x1 Operator’s Manual
(This page intentionally left blank.)
6
Section 2 Operation
2
6
3
4
5
1
Refer to the Operating Controls and Indicators section on the next page for a description of each number.All references to Base PowerCharger 1x1 refer to AutoTest and QuickCharge unless otherwise specified.
7
ZOLL Base PowerCharger 1x1 Operator’s Manual
2SHUDWLQJ&RQWUROVDQG,QGLFDWRUV The ZOLL Base PowerCharger with AutoTest automatically tests battery capacity with each battery recharge. In addition, the ZOLL Base PowerCharger 1x1 with AutoTest illuminates the BATT. READY indicator when the battery is fully charged. Fully charged batteries whose capacity is insufficient will cause the FAULT light to illuminate. See the M Series Operator's Manual for run time information. With AutoTest, the full charging cycle is complete in 8 hours or less for the PD 4410/Smart Battery and 15 hours or less for the XL Smart Battery. 1x1
The ZOLL Base PowerCharger 1x1 with QuickCharge provides no information regarding battery capacity because it does not test the battery capacity with each recharge. The ZOLL Base PowerCharger 1x1 with QuickCharge relies on the user to manually initiate the battery test cycle at recommended intervals (see Manual Battery Testing Procedure) in order to confirm adequate battery capacity.The Base PowerCharger 1x1 with QuickCharge illuminates the BATT. READY indicator when the battery is fully charged. The full charging cycle is complete in 4 hours or less for the PD 4410/Smart Battery and 8 hours or less for the XL Smart Battery.
32:(5 Illuminates when the Base PowerCharger 1x1 is connected to live AC mains and the unit is ready for charging and/or testing.
&+$5*(521 Illuminates when a battery is properly installed in the charging/testing compartment and the test/charge cycle is in progress. Illuminates with the TESTING light during AutoTest and recharge of the battery.
%$775($'< AutoTest Illuminates at the end of a test/charge cycle to indicate that the battery has been charged to 100% of its present capacity and is ready for use. Indicates the battery compartment or battery has passed the capacity test and is operating properly.
QuickCharge Illuminates at the end of a charge cycle to indicate that the battery has been charged to 100% of its present capacity and is ready for use. If using a QuickCharge unit the BATT. READY light does NOT give any indication as to the available run time left in the battery.
)$8/7 Illuminates, with the TESTING light, when battery capacity test fails. Also, illuminates when a battery compartment or any other failure occurs.
7(67,1*
8
Illuminates when either battery capacity test cycle is in progress or battery compartment test is completed. Illuminates with the BATT. READY light (Manual Test Only) indicating a good fully charged battery. Illuminates with the FAULT light to indicate a battery that has failed the capacity test. Illuminates with the CHARGER ON light during AutoTest and recharge of the battery.
7(67EXWWRQ Initiates battery test cycle or battery compartment test. The battery capacity test cycle automatically charges, discharges and recharges the battery. If a battery is installed in the battery compartment and the TEST button is pressed, a capacity test is performed. If the battery compartment is empty and the TEST button is pressed, a compartment test is performed.
6HWXS Place the Base PowerCharger 1x1 on a stable secure surface. There must be at least 4 inches of clear space around the unit to allow for proper heat dissipation during charging or testing batteries. Do not place anything on top of or beneath the unit, such as blankets or cloths. Doing so may block the vents on the unit, preventing proper dissipation of heat during operation. Turn the unit on by plugging the line cord into the power module at the rear of the unit and then into live AC mains.
%DWWHU&KDUJLQJ &DXWLRQ • :KHQDIXOOFKDUJHGEDWWHULVSODFHGLQWRWKH%DVH 3RZHU&KDUJHU [ZLWKWKH$XWR7HVWWKH$XWR7HVWZLOO 127DFWLYDWHDQGWKH%$775($'<LQGLFDWRUZLOO LOOXPLQDWHZLWKLQDIHZPLQXWHV6LQFHWKH$XWR7HVW VHTXHQFHLVQRWSHUIRUPHGLWLVSRVVLEOHWRKDYHD VKRUWHUEDWWHUUXQWLPHWKDQH[SHFWHG7RLQLWLDWHD WHVWRIDIXOOFKDUJHGEDWWHUIROORZWKHLQVWUXFWLRQV XQGHUWKH0DQXDO%DWWHU7HVWLQJ3URFHGXUH When using AutoTest, proper placement of the battery into the compartment will automatically initiate the test and charging cycle, however, when using QuickCharge units, only the charging cycle will be initiated. To charge a battery: 1. Check to see that the unit is connected to live AC mains. The POWER light should be lit.
Operation
2. Insert battery into the compartment. Make sure the
battery is fully seated (A click can be heard).
5. To remove the battery, insert a finger into the recess at the top of the battery compartment, press against the battery to disengage the battery locking clip and lift the battery out. A charger test is performed illuminating all LED's briefly followed by the BATT. READY and TESTING indicators illuminating for 2 seconds and then all LED's go off except for the POWER LED.
0DQXDO%DWWHU7HVWLQJ3URFHGXUH
3. The CHARGER ON and TESTING indicators illuminate and remain on during complete AutoTest and recharge cycle (shown). Only the CHARGER ON indicator illuminates during a QuickCharge recharge cycle.
Although this test is available, the Auto Test feature eliminates the need to manually test batteries since battery capacity is automatically tested with each battery recharge (except when a fully charged battery is placed in the unit). It is not necessary to insert a fully charged battery for testing; the Base PowerCharger 1x1 will automatically test the battery regardless of charge status. To test a battery: 1. Check to see that the Base PowerCharger 1x1 is con-
nected to live AC mains. The POWER light should be lit. 2. ,QVHUWEDWWHULQWRWKHFKDUJHU0DNHVXUHWKHEDWWHU
LVIXOOVHDWHG(A click can be heard).
4. In 8 hours or less for the PD 4410/Smart Battery or 15 hours or less for the XL Smart Battery (using AutoTest) the CHARGER ON light will go off and the BATT. READY light will illuminate indicating the battery has passed the capacity test and is fully charged and ready for use. In 4 hours or less for the PD 4410/Smart Battery or 8 hours or less for the XL Smart Battery (using QuickCharge) the CHARGER ON light will go off and the BATT. READY light will illuminate indicating the battery has been charged to 100% of its present capacity and is ready for use.
If the battery or charger is not capable of charging, the FAULT light will illuminate and the CHARGER ON light may stay on. Before discarding the battery, test the battery compartment for defective operation (see Operational Checks Section) and perform a second battery test.
3. Press the TEST button. The TESTING indicator light will illuminate for the duration of the test cycle.
4. If the battery passes the test, the BATT. READY light will illuminate while the TESTING light remains lit indicating the battery is fully charged and ready to use. See the M Series Operator's Manual for run time information. 5. If a battery fails the test, the FAULT light will illuminate while the TESTING light remains lit. Before discarding the battery, test the battery compartment for possible defective operation (See Operational Checks Section). Repeat Battery test. 6. Record the date and results of the test on the battery label.
9
ZOLL Base PowerCharger 1x1 Operator’s Manual
4XLFN5HIHUHQFH&KDUWIRU%DVH3RZHU&KDUJHU [ZLWK$XWR7HVW 7KHIROORZLQJFKDUWGHVFULEHVWKHRSHUDWLRQRIWKH%DVH3RZHU&KDUJHU[ZLWK$XWR7HVW7KHFKDUWRQWRSUHSUHVHQWV QRUPDO/('RSHUDWLRQIRUWKH%DVH3RZHU&KDUJHU[ZLWK$XWR7HVWZKHQDJRRGEDWWHULVLQVWDOOHGLQWKH FRPSDUWPHQW7KHERWWRPFKDUWUHSUHVHQWVWKH%DVH3RZHU&KDUJHU[ZLWK$XWR7HVWZKHQDEDGEDWWHULVLQVWDOOHGLQ WKHFRPSDUWPHQW,OOXPLQDWLRQRIVSHFLILFLQGLFDWRUOLJKWVWRJHWKHUUHSUHVHQWDVSHFLILFPRGHRIRSHUDWLRQGHVFULEHGLQ WKH'HVFULSWLRQFROXPQ
/('1250$/23(5$7,21*22'%$77(5< &+$5*(521 $XWR7HVW ZLWK%DWWHULQ &RPSDUWPHQW
%$77 5($'<
)$8/7
ON
7(67,1* ON
ON
0DQXDO7HVWZLWK %DWWHULQ &RPSDUWPHQWDQG ³7(67´EXWWRQSXVKHG
'HVFULSWLRQ AutoTest is in progress. AutoTest is complete and the battery is in good condition.
ON
ON
Manual Test is in progress.
ON
Manual Test is complete and the battery is in good condition.
/('23(5$7,21%$'%$77(5< &+$5*(521 $XWR7HVW ZLWK%DWWHULQ &RPSDUWPHQW 0DQXDO7HVWZLWK %DWWHULQ &RPSDUWPHQWDQG ³7(67´EXWWRQSXVKHG
10
%$77 5($'<
)$8/7
ON ON
ON
7(67,1*
'HVFULSWLRQ
ON
AutoTest is in progress.
ON
AutoTest is complete and the battery is NOT usable.
ON
Manual Test is in progress.
ON
Manual Test is complete and the battery is NOT usable.
Operation
4XLFN5HIHUHQFH&KDUWIRU%DVH3RZHU&KDUJHU [ZLWK4XLFN&KDUJH 7KHIROORZLQJFKDUWGHVFULEHVWKHRSHUDWLRQRIWKH%DVH3RZHU&KDUJHU[ZLWK4XLFN&KDUJH7KHFKDUWRQWRS UHSUHVHQWVQRUPDO/('RSHUDWLRQIRUWKH%DVH3RZHU&KDUJHU[ZLWK4XLFN&KDUJHZKHQDJRRGEDWWHULVLQVWDOOHGLQ WKHFRPSDUWPHQW7KHERWWRPFKDUWUHSUHVHQWVWKH%DVH3RZHU&KDUJHU[ZLWK4XLFN&KDUJHZKHQDEDGEDWWHULV LQVWDOOHGLQWKHFRPSDUWPHQW,OOXPLQDWLRQRIVSHFLILFLQGLFDWRUOLJKWVWRJHWKHUUHSUHVHQWDVSHFLILFPRGHRIRSHUDWLRQ GHVFULEHGLQWKH'HVFULSWLRQFROXPQ
/('1250$/23(5$7,21*22'%$77(5< &+$5*(521 4XLFN&KDUJH ZLWK%DWWHULQ &RPSDUWPHQW
%$77 5($'<
)$8/7
7(67,1*
ON
Charging is in progress. ON
0DQXDO7HVWZLWK %DWWHULQ &RPSDUWPHQWDQG ³7(67´EXWWRQSXVKHG
'HVFULSWLRQ
Charging is complete .
ON
ON
Manual Test is in progress.
ON
Manual Test is complete and the battery is in good condition.
/('23(5$7,21%$'%$77(5< &+$5*(521 4XLFN&KDUJH ZLWK%DWWHULQ &RPSDUWPHQW 0DQXDO7HVWZLWK %DWWHULQ &RPSDUWPHQWDQG ³7(67´EXWWRQSXVKHG
%$77 5($'<
)$8/7
7(67,1*
ON
'HVFULSWLRQ Charging is in progress.
ON
ON
Charging is complete and the battery is NOT usable. ON
Manual Test is in progress.
ON
Manual Test is complete and the battery is NOT usable.
11
ZOLL Base PowerCharger 1x1 Operator’s Manual
(This page intentionally left blank.)
12
Section 3
Maintenance and Troubleshooting Following is a list of nontechnical operational checks. These checks should be performed periodically to ensure proper equipment operation. If during this procedure, the operator discovers a malfunction, contact ZOLL Technical Service.
,QVSHFWLRQ Assure that the unit is clean (with no fluid spills) and nothing is stored on the unit. Inspect all batteries for good condition.
&OHDQLQJ Clean the Base PowerCharger 1x1, with a soft cloth, mild soap and water. Do not immerse any part of the Base PowerCharger 1x1 in water. Do not use alcohol or ketones (MEK, acetone, etc.). Do not autoclave the Base PowerCharger 1x1.
2SHUDWLRQDO&KHFNV 1. Connect the unit to live AC mains. All four indicator lights will illuminate for approximately 4-5 seconds.The POWER indicator will remain lit while the other lights go off. 2. With the battery compartment empty, check that all indicator lights except POWER are off. 3. Press the TEST button to check that the unit is fully operational. 4. All four indicator lights will illuminate for approximately 45 seconds.
7URXEOHVKRRWLQJ The troubleshooting guide provided below is intended for use by nontechnical personnel during operation. This section answers many of the common problems or questions that arise during operation. If trouble persists after consulting this guide, call ZOLL and ask for the Technical Service Department. 1. POWER light does not illuminate. •Check that unit is plugged into an appropriate power source. •Check for defective power cord.
•Plug unit into another power source. •Check for blown fuse. 2. CHARGER ON indicator light does not illuminate when battery is in compartment. •Check that battery is properly seated in compartment.
•Check that battery contacts are clean and not damaged.
•Check that unit is plugged into an appropriate power source.
•Test the battery compartment for functionality. •Place another battery in the compartment. 3. TESTING light does not illuminate when TEST button is pressed. •Check that battery is properly seated in compartment.
•Check that unit is plugged into an appropriate power source.
5. If the TESTING light and BATT. READY light remain lit for three seconds while the other lights go off, the unit is fully operational without any defects.
•Verify that battery compartment is fully operational with
6. If the FAULT light remains lit, the unit is defective.
•Repeat test cycle. •,IEDWWHUIDLOVVHFRQGWHVWUHPRYHEDWWHUIURPuse.
,QVHUWDEDWWHULQWRWKHFRPSDUWPHQW9HULIWKDWWKH &+$5*(521OLJKWLOOXPLQDWHVLPPHGLDWHO
no defects.
13
ZOLL Base PowerCharger 1x1 Operator’s Manual
(This page intentionally left blank.)
14
Section 4 Battery Management Safe, reliable use of all ZOLL devices require a well designed battery management program to ensure that adequate battery power is always available. The 6 key steps to developing a battery program are: 1. Obtain proper equipment. Plan to have a sufficient number of battery packs and chargers to insure an adequate supply of fully charged primary use and spare use batteries. 2. Assign a responsible individual. Assign the responsibility to an individual who can oversee all aspects of the program as well as educate other ZOLL Monitor/Defibrillator users. 3. Define battery exchange and charging routines. Clinical and technical staff should determine desired use patterns and an optimum sequence to insure consistent charging and exchange routines. 4. Ensure sufficient spare battery capability. A fully-charged spare battery should be kept immediately available with all ZOLL Monitor/Defibrillator devices. The availability of more than one spare battery is recommended in cases where prolonged or repeated use of the device may be required, such as long transport situations. 5. Develop backup procedures. Procedures to maintain appropriate life support (such as cardiopulmonary resuscitation) should be pre-planned in the event of a device failure and another battery or device must be sought. 6. Test batteries regularly.
'HYHORSDWHVWLQJVFKHGXOHDVSDUWRIRXU RUJDQL]DWLRQ¶VEDWWHUPDQDJHPHQWSURJUDP7KH DSSURSULDWHIUHTXHQFRIWHVWLQJGHSHQGVRQWKHDJH RIWKHEDWWHUSDFNDQGWKHIUHTXHQFDQGWSHRI XVH$VWKHEDWWHUDJHVWHVWLQJVKRXOGEHPRUH IUHTXHQWVLQFHIDLOXUHZLOORFFXUUDSLGODWWKHEDWWHU¶V HQGRIOLIH$WDPLQLPXP=2//UHFRPPHQGVWHVWLQJ HYHUWKUHHPRQWKV)RUDGGLWLRQDOLQIRUPDWLRQRQ %DWWHU0DQDJHPHQWUHIHUWRWKH=2//%DWWHU 0DQDJHPHQW3URJUDP RUGHU
=2//%DWWHU3DFNV The ZOLL Battery Pack is a five-cell assembly of sealed lead-acid batteries specifically designed for use with all ZOLL Monitor/Defibrillator devices. Lead acid battery packs require full recharging after use. Continuous short cycle recharging will result in reduced capacity and early battery pack failure.
%DWWHU/LIH([SHFWDQF Frequency of use, number of batteries used, and the pattern of discharging and recharging batteries contribute to the loss of battery charge capacity. Because of this ZOLL recommends that operators replace and discard used batteries on a preventive, scheduled basis. The most effective preventive replacement interval should be based on anticipated use patterns, battery pack testing results and experience with the device in actual operation. ZOLL recommends battery replacement every eighteen months or sooner. For more information about such a schedule, contact your ZOLL Technical Service Representative.
/RZ%DWWHU0HVVDJH As individual battery capacity diminishes, the amount of operating time remaining after a LOW BATTERY message also diminishes. For newer or lesser-used batteries, the operating time remaining after this warning will be significantly longer than the operating time remaining on batteries having seen more use. In either case, this warning will ultimately lead to defibrillator shut-off, and consequently, the low battery should be replaced with a fully-charged battery as soon as possible. When a LOW BATTERY message is displayed, replace the battery pack immediately to ensure continuous operation.
%DWWHU'LVSRVDO 3ODFHWKHEDWWHULQDQDFLGUHVLVWDQWFRQWDLQHU'LVSRVH RIWKHEDWWHULQDFFRUGDQFHZLWKIHGHUDOVWDWHDQGORFDO UHJXODWLRQV'RQRWLQFLQHUDWHEDWWHULHV%DWWHULHVVKRXOG EHVKLSSHGWRDUHFODPDWLRQIDFLOLWIRUUHFRYHURIPHWDO DQGSODVWLFFRPSRXQGVDVWKHSURSHUPHWKRGRIZDVWH PDQDJHPHQW
15
ZOLL Base PowerCharger 1x1 Operator’s Manual
(This page intentionally left blank.)
16
Section 5 EMC Specifications *XLGDQFHDQG0DQXIDFWXUHU¶V'HFODUDWLRQ(OHFWURPDJQHWLF(PLVVLRQV The ZOLL Base PowerCharger 1x1 is intended for use in the electromagnetic environment specified below. The customer or the user of the ZOLL Base PowerCharger 1x1 should ensure that it is used in such an environment. Emissions test
Compliance
Electromagnetic environment - guidance
RF emissions CISPR11
Group 1
The ZOLL Base PowerCharger 1x1 uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.
RF emissions CISPR 11
Class B
Harmonic Emission
Not applicable
IEC 61000 3-2 Voltage Fluctuations/Flicker Emission
Not applicable
IEC 61000 3-3 Medical Electrical Equipment needs special precautions regarding EMC and needs to be installed and put into service according to EMC information provided in this document.
17
ZOLL Base PowerCharger 1x1 Operator’s Manual
*XLGDQFHDQG0DQXIDFWXUHU¶V'HFODUDWLRQ(OHFWURPDJQHWLF,PPXQLW The ZOLL Base PowerCharger 1x1 is intended for use in the electromagnetic environment specified below. The customer or the user of the ZOLL Base PowerCharger 1x1 should ensure that it is used in such an environment. Immunity test
IEC 60601 test level
Compliance level
Electromagnetic environment - guidance
Electrostatic discharge (ESD) IEC 61000-4-2
± 6 kV contact
± 6 kV contact
± 8 kV air
± 8 kV air
Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%.
Electrical fast transient/burst IEC 61000-4-4
± 2 kV for power supply lines
± 2 kV for power supply lines
Mains power quality should be that of a typical commercial or hospital environment.
± 1 kV for input/output lines
± 1 kV I/O
Surge
± 1 kV differential mode
± 1 kV differential mode
+/- 2 kV common mode
+/- 2 kV common mode
<5% Ut (>95% dip in Ut) for 0.5 cycle
<5% Ut (>95% dip in Ut) for 0.5 cycle
40% Ut (60% dip in Ut) for 5 cycles
40% Ut (60% dip in Ut) for 5 cycles
70% Ut (30% dip in Ut) for 25 cycles
70% Ut (30% dip in Ut) for 25 cycles
<5% Ut (>95%dip in Ut) for 5 sec
<5% Ut (>95%dip in Ut) for 5 sec
3 A/m
3 A/m
IEC 61000-4-5
Voltage dips, short interruptions and voltage variations on power supply input lines. IEC 61000-4-11
Power frequency (50/60 Hz) magnetic field IEC 61000-4-8
1RWH 8WLVWKHDFPDLQVYROWDJHSULRUWRDSSOLFDWLRQRIWKHWHVWOHYHO
18
Mains power quality should be that of a typical commercial or hospital environment.
Mains power quality should be that of a typical commercial or hospital environment. If the user of the ZOLL Base PowerCharger 1x1 requires continued operation during mains interrupting, it is recommended that the ZOLL Base PowerCharger 1x1 be powered from an uninterruptible power supply.
Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment