TIR-1™ Thermometer
These operating instructions provide the necessary information for proper operation of all models of the TIR-1. There may be information provided in this manual that is not relevant for your system. General knowledge of pulse oximetry and an understanding of the features and functions of TIR-1 are prerequisites for its proper use. Do not operate TIR-1 without completely reading and understanding these instructions. CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. For professional use. See instructions for use for full prescribing information, including indications, contraindications, warnings, and precautions. TaiDoc Technology Corporation B1-7F, No.127, Wugong 2nd Road, Wugu Dist. 24888 New Taipei City, Taiwan Distributed by: Masimo Corporation 52 Discovery Irvine, CA 92618, USA Tel.: 949-297-7000 Fax.: 949-297-7001 www.masimo.com
5009094
MEDICAL ELECTRICAL EQUIPMENT WITH RESPECT TO ELECTRIC SHOCK, FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH AAMI ES60601-1, IEC 60601-1 & ISO 80601-2-56. Certified to STD C22.2 #60601-1 Standards for which the product has been found to comply by Intertek.
Patents: www.masimo.com/patents Root®, Masimo® and
®, are federally registered trademarks of Masimo Corporation.
TIR-1™ is a trademark of Masimo Corporation. All other trademarks and registered trademarks are property of their respective owners. © 2018 Masimo Corporation
www.masimo.com
1
Masimo
Contents About this Manual ------------------------------------------------------------------------------------------ 5 Product Description, Features and Intended Use ------------------------------------------------------7 Product Description --------------------------------------------------------------------------------------7 Intended Use ---------------------------------------------------------------------------------------------7 Safety Information, Warnings and Cautions ----------------------------------------------------------- 9 Safety Warnings and Cautions ------------------------------------------------------------------------ 9 Performance Warnings and Cautions ---------------------------------------------------------------- 9 Cleaning and Service Warnings and Cautions ---------------------------------------------------- 10 Compliance Warnings and Cautions ---------------------------------------------------------------- 10 Chapter 1: Technology Overview ------------------------------------------------------------------------ 13 About Body Temperature and Fever ---------------------------------------------------------------- 13 Chapter 2: Description ------------------------------------------------------------------------------------ 15 General System Description -------------------------------------------------------------------------- 15 Features -------------------------------------------------------------------------------------------------- 15 Bluetooth Function ------------------------------------------------------------------------------------ 16 Chapter 3: Basic Setup and Use------------------------------------------------------------------------- 17 Installing Batteries ------------------------------------------------------------------------------------ 17 Body Temperature Measurement-------------------------------------------------------------------- 18 Pairing TIR-1 to a Masimo Device ------------------------------------------------------------------- 18 Chapter 4: Operation -------------------------------------------------------------------------------------- 21 TIR-1 Stand-Alone ------------------------------------------------------------------------------------- 21 TIR-1 with Root ----------------------------------------------------------------------------------------- 23 Chapter 5: Alarms and Messages ----------------------------------------------------------------------- 31 Alarms---------------------------------------------------------------------------------------------------- 31 TIR-1 Messages ----------------------------------------------------------------------------------------- 31 Root Messages ------------------------------------------------------------------------------------------ 32 Chapter 6: Troubleshooting ----------------------------------------------------------------------------- 33 Chapter 7: Specifications -------------------------------------------------------------------------------- 35 Display Range ------------------------------------------------------------------------------------------ 35 Accuracy ------------------------------------------------------------------------------------------------ 35 Resolution ---------------------------------------------------------------------------------------------- 36 www.masimo.com
3
Masimo
TIR-1 Thermometer
Contents
Response Time ----------------------------------------------------------------------------------------- 36 Electrical------------------------------------------------------------------------------------------------- 37 Environmental------------------------------------------------------------------------------------------ 37 Physical Characteristics ------------------------------------------------------------------------------ 37 Compliance --------------------------------------------------------------------------------------------- 37 Wireless Specifications ------------------------------------------------------------------------------- 38 Guidance and Manufacturer's Declaration-Electromagnetic Emissions---------------------- 39 Guidance and Manufacturer's Declaration-Electromagnetic Immunity ---------------------- 40 Symbols-------------------------------------------------------------------------------------------------- 42 Chapter 8: Service and Maintenance ------------------------------------------------------------------ 45 Maintenance and Cleaning -------------------------------------------------------------------------- 45 Service and Return Procedure ----------------------------------------------------------------------- 45 Contacting Masimo ------------------------------------------------------------------------------------ 46 Index --------------------------------------------------------------------------------------------------------- 49
www.masimo.com
4
Masimo
About this Manual This manual explains how to set up and use TIR-1™ Thermometer. Important safety information relating to general use of TIR-1 appears in this manual. Read and follow any warnings, cautions, and notes presented throughout this manual. The following are explanations of warnings, cautions, and notes. A warning is given when actions may result in a serious outcome (for example, injury, serious adverse effect, death) to the patient or user. WARNING: This is an example of a warning statement. A caution is given when any special care is to be exercised by the patient or user to avoid injury to the patient, damage to this device, or damage to other property. CAUTION: This is an example of a caution statement. A note is given when additional general information is applicable. Note: This is an example of a note.
www.masimo.com
5
Masimo
Product Description, Features and Intended Use Product Description The TIR-1™ Thermometer is a noninvasive, infrared, clinical thermometer that can be used as a standalone device or with Masimo devices.
Features Features of TIR-1 include: •
Fast measurement that meets ASTM and ISO standards.
•
Simple 1-button operation, no scanning required.
•
Audible and visual indication of completed temperature.
•
Backlit LCD display and Low Battery indication.
•
Long Battery Life of more than 10,000 temperatures (typical).
•
Memory recall of up to 30 temperature readings (with date and time stamp).
•
Can communicate via Bluetooth LE to Masimo devices.
Intended Use TIR-1™ Thermometer is an infrared thermometer intended for the measurement of human body temperature in people of all ages without contact to the body and is to be used by medical professionals.
www.masimo.com
7
Masimo
Safety Information, Warnings and Cautions The manual, accessories, directions for use, all precautionary information, and specifications should be read before use. Refer to Masimo Operator's Manuals for additional safety information, warnings, and cautions.
Safety Warnings and Cautions WARNING: Do not use TIR-1 during magnetic resonance imaging (MRI) or in an MRI environment. WARNING: Do not place TIR-1 or accessories in any position that might cause it to fall on the patient. WARNING: Do not use TIR-1 during defibrillation. WARNING: Do not use TIR-1 during electrosurgery. WARNING: Do not use TIR-1 in the presence of flammable anesthetics or other flammable substances, oxygen-enriched environments, or nitrous oxide to avoid the risk of explosion. WARNING: Do not leave the TIR-1 unattended around children. Small items such as the battery door, battery, and lanyard may become choking hazards.
Performance Warnings and Cautions WARNING: TIR-1 should not be used as the sole basis for medical decisions. It must be used in conjunction with clinical signs and symptoms. WARNING: Do not use TIR-1 if it appears or is suspected to be damaged. Damage to internal parts can result in no or inaccurate readings. WARNING: Do not repair, open, or modify TIR-1. Damage to internal parts can result in no or inaccurate readings. WARNING: Do not use the TIR-1 if the internal parts have been exposed to liquids. Damage to the internal parts may result in no or inaccurate readings. CAUTION: Remove perspiration and excess oil from the forehead as this may affect the accuracy of the reading. CAUTION: Do not use on patients with the following as they may affect the accuracy of the readings: •
Scarred tissue or tissue compromised by skin disorders or trauma in the vicinity of the forehead measurement area.
•
Patients treated with certain drug therapies that may affect normal body temperature or use on patients while skin is exposed to external sources of heat or cold such as direct sunlight, fireplace heat, cold compress therapies, air conditioner flow, etc.
CAUTION: Keep the TIR-1 away from electrical equipment that emits radio frequencies to minimize radio interference. Radio interference may result in no or inaccurate readings. www.masimo.com
9
Masimo
TIR-1 Thermometer
Safety Information, Warnings and Cautions
CAUTION: When using the TIR-1 Thermometer connected via Bluetooth, keep both devices within the recommended 8 to 10 feet range of each other; moving outside of this range may cause a loss in connection. CAUTION: When paired to a Masimo device, the time and date of the Masimo device is used as the time stamp. CAUTION: When paired to a Masimo device, the temperature unit of measure of TIR-1 and the Masimo device is are not synchronized. Note: If coming from a warmer or cooler environment or after a period of exertion, allow the patient and thermometer to acclimate to room temperature for 20 minutes prior to taking temperature. Note: Replace protective sensor cap when not in use.
Cleaning and Service Warnings and Cautions WARNING: Properly use and dispose of Alkaline batteries or they may leak or explode. WARNING: Remove alkaline batteries when the TIR-1 will not be in use for more than 30 days to avoid damage to the device due to batteries that may leak. WARNING: Replace both batteries at the same time to avoid mixing fully and partially charged batteries. These actions may cause the batteries to leak; resulting in possible damage to the device. CAUTION: Use only AA alkaline batteries. Use of non-alkaline batteries may affect the accuracy of the battery status indicator. CAUTION: Only perform maintenance procedures specifically described in the manual; otherwise, return TIR-1 for servicing. Improper maintenance may result in damage to the internal parts. Damage to internal parts may result in no or inaccurate readings. CAUTION: Do not clean TIR-1 with any chemical other than those specified in Maintenance and Cleaning of this manual. These substances may affect the device’s materials and damage internal parts. CAUTION: Do not submerge TIR-1 in any cleaning solution or attempt to sterilize by autoclave, irradiation, steam, gas, ethylene oxide or any other method. This will seriously damage the device. CAUTION: Do not use undiluted bleach (5% - 5.25% sodium hypochlorite) or any cleaning solution other than those recommended in Maintenance and Cleaning of this manual. Permanent damage to TIR-1 may occur if other unspecified solutions are used. CAUTION: Never submerge TIR-1 in water or any other liquid solution this may cause permanent damage to the TIR-1. Note: Ensure that sensor end is clean and free of debris. See Maintenance and Cleaning of this manual for proper cleaning instructions.
Compliance Warnings and Cautions WARNING: Any changes or modifications not expressly approved by Masimo shall void the warranty for this equipment and could void the user’s authority to operate the equipment. CAUTION: Comply with local laws in the disposal of the instrument and/or its accessories, including batteries. www.masimo.com 10 Masimo
TIR-1 Thermometer
Safety Information, Warnings and Cautions
Note: When using The TIR-1 with a device with wireless features, consideration should be taken to local government frequency allocations and technical parameters to minimize the possibility of interference to/from other wireless devices. Note: In accordance with international telecommunication requirements, the frequency band of 2.4 GHz is only for indoor usage to reduce potential for harmful interference to co-channel mobile satellite systems. Note: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Consult the dealer or an experienced radio/TV technician for help.
Note: This equipment has been tested and found to comply with the Class B limits for medical devices according to the EN 60601-1-2: 2007, Medical Device Directive 93/42/EEC. These limits are designed to provide reasonable protection against harmful interference in all establishments, including domestic establishments. Note: This Class B digital apparatus complies with Canadian ICES-003. Note: This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
www.masimo.com
11
Masimo
Chapter 1: Technology Overview About Body Temperature and Fever Body temperature can vary from one person to the next and also varies by location on the body and time of day. Temperatures measured from different sites, even at the same time, should not be directly compared. Fever indicates that body temperature is higher than normal. This may be caused by a number of conditions including infection, overexertion, overdressing or immunization. Some people may not experience fever even when they are ill. These include, but are not limited to, infants younger than 3 months old, persons with compromised immune systems, persons taking antibiotics, steroids or antipyretics (aspirin, ibuprofen, acetaminophen), or persons with certain chronic illnesses. Please consult your physician when you feel ill even if you do not have fever.
www.masimo.com
13
Masimo
Chapter 2: Description General System Description The TIR-1™ Thermometer includes: •
The TIR-1 device
•
Two (2) AA alkaline batteries
•
Infrared sensor cover
Features Display 1. Low battery indicator 2. Date Indicator 3. Date/Time 4. Temperature Reading 5. Object Surface Temperature Indicator 6. Body Temperature Indicator
www.masimo.com
15
7. Room Temperature Indicator 8. Bluetooth indicator 9. Memory Mode 10. Unit of Measurement °F/°C 11. Error Warning
Masimo
TIR-1 Thermometer
Chapter 2: Description
Controls 1. 2. 3. 4. 5. 6. 7. 8.
Power/Start Measurement Bluetooth LED Infrared Sensor Change Scale °C/°F SET: Set Date/Time Battery Compartment MEM: Recall Stored temperature MODE: Body, Surface, or Room
Bluetooth Function Temperature may be transmitted from TIR-1 to a Masimo device using a Bluetooth connection. Pairing must be completed before data will be received. To pair TIR-1 to a Masimo device, see Pairing TIR-1 to a Masimo Device on page 18.
Bluetooth Indicator and LED The Bluetooth indicator on the display remains solid and does not indicate connection status. The Bluetooth LED indicates connection status. Bluetooth LED Status Flashing
Bluetooth function ON and waiting for connection
Solid
Bluetooth connection is established
www.masimo.com
16
Masimo
Chapter 3: Basic Setup and Use The following information provides instructions to setup TIR-1 and begin taking patient temperatures, as well as pair to a Masimo device. 1. 2. 3.
Install batteries into TIR-1. Take a patient's temperature using TIR-1. Pair TIR-1 to a Masimo device to display patient's temperature measurements on the Masimo device screen.
Installing Batteries 1. 2. 3.
To remove Battery Cover, press down at the arrow mark and also on the center of the cover; SLIDE it in the direction of the arrow as shown in Figure 1. Install (2) AA alkaline batteries with polarity as shown in the battery compartment. All LCD display segments will briefly illuminate during self-test, and you will hear a “beep”. Close the battery cover by pressing down both the arrow mark and the bottom of the cover, SLIDING the cover in the opposite direction of the arrow as shown in Figure 2.
Figure 1
Figure 2
Figure 3
DO NOT press the battery cover to force it closed. If the battery cover does not close tight as shown in Figure 3, remove the battery cover by SLIDING as described in Step 1. Repeat Step 3 to close the battery cover tight. CAUTION: Closing the battery cover by force may damage the battery cover latch and result in battery damage. Always follow the instructions and close the battery cover by SLIDING only. •
Set Date and Time as described in Setting Date/Time on page 21.
•
TIR-1 defaults to °F temperature scale and BODY mode.
Note: If TIR-1 will be stored for a long period, remove the batteries.
www.masimo.com
17
Masimo
TIR-1 Thermometer
Chapter 3: Basic Setup and Use
Body Temperature Measurement 1.
2.
Remove the protective cap (if installed) and inspect the sensor. Remove any debris and clean the sensor as necessary. Remove hair and perspiration from center forehead area as shown in Figure 1. •
Figure 1
If the patient was lying face down or was wearing a hat or garment covering the skin, allow the forehead to be exposed to the air in the room for 5 minutes prior to taking reading.
•
3.
Figure 2
4.
5.
Relocate patient if in drafty environment. Aim at center forehead area 1/2" to 2" (1.2 to 5 cm) away from skin surface. Be sure thermometer is perpendicular to skin surface (at right angle) as shown in Figure 2. Press and release the Power/Start Measurement button. See Features on page 15. Hold thermometer in place until a double beep is heard and the temperature is displayed on the LCD. Ensure the Body temperature icon is displayed. See Display on page 15. If properly paired to a Masimo device, the TIR-1 reading also displays in the Temperature window on the Main Screen. See Temperature Window on page 23.
For additional information on TIR-1 operation such as changing temperature scale and modes, see Chapter 4: Operation on page 21. Note: If temperature is suspected to be incorrect or display reads LO or HI, see TIR-1 Messages on page 31.
Pairing TIR-1 to a Masimo Device Note: Verify compatibility between the TIR-1 and the Masimo device before attempting to pair. Note: If pairing TIR-1 to a Root with noninvasive blood pressure and temperature, the temperature probe must be disabled. See Active Channels on page 26.
www.masimo.com
18
Masimo
TIR-1 Thermometer
Chapter 3: Basic Setup and Use
To pair TIR-1 with a Masimo device: 1. 2. 3. 4. 5. 6.
7.
On the Masimo device, at the bottom right corner of the touchscreen, press the Main Menu icon . Select the Device Settings menu icon. Select the Bluetooth menu icon. On the Bluetooth screen, ensure Bluetooth is turned On. Select the Thermometer Pair button. To place TIR-1 into paring mode, take a measurement. See Body Temperature Measurement on page 18. The Bluetooth indicator appears on the display and the Bluetooth LED blinks. See Bluetooth Indicator and LED on page 16. Note: TIR-1 remains in pairing mode until it powers down (Sleep Mode) after 30 seconds of non-use. Note: To exit pairing mode, press the MODE, SET, MEM or C/F buttons. After the measurement is taken and the LED is blinking (within the 30 seconds after being placed in pairing mode), hold the TIR-1 close to the Masimo device (Root shown in the example).
8.
TIR-1 should appear under the Devices Found list on the Masimo device screen. Select the TIR-1 thermometer under the Devices Found list. Note: The MAC Address for TIR-1 may also be displayed next to the name to assist in identifying the correct thermometer to pair. 9. Select the Pair button. TIR-1 will pair with the Masimo device. 10. After successfully pairing, each measurement taken using TIR-1 is displayed in the Temperature window on the Main Screen of the Masimo device. See Temperature Window on page 23. Note: TIR-1 can be paired to multiple Masimo devices, however, TIR-1 will only send measurements to the last device it communicated with.
www.masimo.com
19
Masimo
Chapter 4: Operation The following information describes TIR-1 operation and settings on Root when properly paired using the Bluetooth connection and is to be used with the information in the Operator's Manual for Root and Operator's Manual for Root with noninvasive blood pressure and temperature.
TIR-1 Stand-Alone The following information provides instructions for settings and temperature memory recall on TIR-1.
Power ON/OFF TIR-1 is powered on by pressing the Power/Start Measurement button. See Features on page 15. TIR-1 automatically powers down (Sleep Mode) after 30 seconds of non-use.
Setting Date/Time The time and date displayed on TIR-1 are both set using the following procedure. This setting is necessary at initial setup and when the batteries are changed. CAUTION: When TIR-1 is paired to a Masimo device, the time and date of the Masimo device is used as the time stamp. To synchronize the date/time of the TIR-1 to the Masimo device, adjust the date/time settings on the TIR-1 to match the Masimo device. 1. 2.
Press the Power/Start Measurement button to turn TIR-1 ON. Press and hold the SET button until the currently set date displays. The "months" digits flash. See Display on page 15. 3. Press the MODE button to increase (+) the month or press the °C/°F button to decrease (-) the month. 4. Press the SET button to save the month and change the day. The "day" digits flash. 5. Press the MODE button to increase (+) the day or press the °C/°F button to decrease (-) the day. 6. Press the SET button to save the day and change the year. The "year" digits flash. 7. Press the MODE button to increase (+) the year or press the °C/°F button to decrease (-) the year. 8. Press the SET button to save the year and change the hour and AM/PM. The "hour" digits flashes and "AM" or "PM" displays. 9. Press the MODE button to increase (+) the hour or press the °C/°F button to decrease (-) the hour. The AM or PM setting is determined by the hour setting. 10. Press the SET button to save the hour and change the minutes. The "minutes" digits flash. 11. Press the MODE button to increase (+) the minutes or press the °C/°F button to decrease (-) the minutes. 12. Press the SET button to save the date and time settings. TIR-1 automatically turns OFF. www.masimo.com
21
Masimo
TIR-1 Thermometer
Chapter 4: Operation
Changing Temperature Scale The temperature scale may be changed to Celsius or Fahrenheit using the following procedure. When properly paired, the temperature scale setting on TIR-1 determines the displayed temperature scale on the Masimo device. The Masimo device temperature scale settings cannot change the temperature scale settings on TIR-1. 1. 2. 3. 4.
Press the Power/Start Measurement button to turn TIR-1 ON. Press and hold the °C/°F button until a single beep is heard. The current scale is displayed. See Display on page 15. Press the °C/°F button again to change scale. When the desired scale is displayed, press the Power/Start Measurement button to save the scale setting and exit this function.
Operation Modes Body Temperature Mode In Body temperature mode, the icon at the left is shown on the display and temperature is adjusted to an oral (sublingual) temperature approximation. See Display on page 15. Normal oral temperature is typically 95.0°F to 100.7°F (35.0°C to 38.2°C) but varies by age, gender and time of day [1]. Body is the default mode of operation. [1] Sund-Levander, M., Forsberg, C. & Wahren, L. (2002). Normal oral, rectal and axillary body temperature in adult men and women; a systematic review. Scandinavian Journal of Caring Science, 16(2), 122-128.
Surface and Room Temperature Modes Surface temperature mode measures the surface temperature of an object placed within the Field Of View (FOV) of the thermometer. At 2" (5cm) away, the FOV is a 0.84" (2.1cm) circle (±8° cone angle FOV). Accuracy varies with the type of object being measured and the temperature of the surrounding environment. Room temperature mode measures the temperature of the room in which the thermometer is located. Allow 20 minutes for the thermometer to adjust to abrupt changes in room temperature.
Setting Mode of Operation TIR-1 remains in the set Mode with each press of the Power/Start Measurement button. If TIR-1 is allowed to power OFF (as opposed to pressing the Power/Start Measurement button and taking a new measurement), the Mode changes back to Body. 1. 2.
Press the Power/Start Measurement button to turn TIR-1 ON. Press and hold the MODE button until a beep is heard and the currently set mode (Body, Surface or Room) flashes. See Display on page 15. 3. Press the MODE button until the desired mode displays. 4. Press the Power/Start Measurement button to save the mode setting and exit this function. www.masimo.com 22 Masimo
TIR-1 Thermometer
Chapter 4: Operation
Temperature Recall Up to 30 temperature measurements are stored on TIR-1 memory and can be viewed at a later time. Once 30 are reached, the oldest is deleted with each new measurement thereafter. If only 10 temperature readings are stored, only 10 stored temperatures can be recalled and displayed. Note: The stored temperature measurements on TIR-1 cannot be recalled on the Masimo device. The Masimo device records temperature measurements separately. See Temperature Window on page 23. 1. 2.
3. 4. 5.
Press the Power/Start Measurement button to turn TIR-1 ON. Press and hold the MEM button. The date and a number from 1 to 30 display indicating the stored temperature number. See Display on page 15. Example: DATE 03/12/2018; 01 (01 is the most recent temperature measurement and 30 is the oldest). Release the MEM button. The time, temperature reading and mode displays. Example: 12:26AM; 98.6 °F; SURFACE. Press and release the MEM button to cycle through the stored temperatures. Press the Power/Start Measurement button to exit this function.
TIR-1 with Root The following information describes TIR-1 operation and settings on Root when properly paired using the Bluetooth connection and is to be used with the information in the Operator's Manual for Root and Operator's Manual for Root with noninvasive blood pressure and temperature.
Temperature Window
Ref. Feature
Description
1
Indicates current reading of the measurement. Touch to access settings.
Numeric Value
www.masimo.com
23
Masimo
TIR-1 Thermometer
Chapter 4: Operation
Ref. Feature
Description
2
Trend Graph
Displays measurements taken over a period of time. Touch to display measurement. See Trends for Temperature on page 27.
3
Alarm Limits and Unit of Measure
Indicates high and low alarm limits and the selected unit of measurement. Touch to access settings. See Alarms for Temperature on page 27 and Alarms for Temperature on page 27.
After successfully pairing TIR-1 with the Masimo device, the temperature and scale data is transmitted with each measurement taken. The reading is displayed in the Temperature window on the Main Screen of the Masimo device, and the TIR-1 name is displayed at the top of the window (Root shown in the example). Note: If pairing TIR-1 to a Root with noninvasive blood pressure and temperature, the temperature probe must first be disabled before the reading can be displayed. See Active Channels on page 26.
Accessing Main Menu Options To access the Main Menu options At the bottom right corner of the touchscreen, press the Main Menu icon.
On Root and Root with NIBP devices, with TIR-1 connected, the following Main Menu option content changes. Layout See Layout on page 25. Temperature See Temperature on page 26. Device Settings See Device Settings on page 28. About See About on page 29.
www.masimo.com
24
Masimo
TIR-1 Thermometer
Chapter 4: Operation
Layout
The Layout menu allows the user to view and customize settings for the Main Screen Layout through the following options: Available layouts See Available Layouts on page 25. Active Channels* See Active Channels on page 26. * Applies to Root with noninvasive blood pressure and temperature only.
Available Layouts When a Radical-7 or Radius-7 is docked to Root and/or multiple MOC-9 modules and TIR-1 are connected, the user will have the option to select from several pre-configured layouts. Image below shows layout options available with Radical-7 docked in Root with SedLine connected through MOC-9, and TIR-1 is connected through Bluetooth. Note: On Root with noninvasive blood pressure and temperature, the layouts are the same, as only the device measuring temperature changes.
www.masimo.com
25
Masimo