medtronic

0° Light Reference Frame

Computer Aided Surgery Systems Equipment Cleaning and Sterilization Instructions

14 Pages

Computer-Aided Surgery Systems Equipment Cleaning and Sterilization 800 595 9709 Toll Free 720 890 3200 Local and International  Equipment Cleaning and Sterilization How to use these instructions Follow these instructions for use for Medtronic devices listed in the “Index of Devices” on page 11. These instructions are intended for critical devices. 1.  Locate the device by part number in the “Index of Devices.” If you cannot locate your device in this list, contact Medtronic Navigation™technical support at 800 595 9709 or 720 890 3160.  2.  Determine which cleaning and sterilization instruction set to use for that device. Instruction sets are given by number and color designation.  3.  Locate the instruction set within this document.  4.  Follow those instructions for that specific device.  5.  Devices must be thoroughly cleaned in a dedicated cleaning area.  Instruction sets Instructions for devices that must be cleaned using automated washer/disinfectors without sonication, or cleaned manually with sonication ...page 2 Instructions for wired (active) devices that must be cleaned using manual methods ...page 5 Instructions for devices that must be cleaned using automated washer/disinfectors with sonication, or cleaned manually with sonication ...page 7  Warnings Warning: Pre-sterilized single-use devices have the single-use symbol on the label. Do not reprocess, resterilize, or reuse any single-use device. Attempts to reprocess or resterilize a single-use device may be ineffective and may compromise its structural integrity. Any reuse creates a risk of contamination which could result in patient injury, illness, or death. Warning: Do not reuse or reprocess the device where transmissible spongiform encephalopathies or Creutzfeldt-Jakob disease contamination is suspected. Incinerate the potentially contaminated device according to national guidelines. Warning: To prevent cross-contamination, always handle, transport, and reprocess devices contacting the central nervous system separately from other devices. Warning: To avoid potential exposure to blood-borne pathogens and chemicals, use appropriate Personal Protective Equipment when handling, reprocessing, or disposing of the device. Universal precautions should be observed by all personnel according to OSHA Standard 29 CFR 1910.1030, Occupational Exposure to Bloodborne Pathogens. Warning: The device is designed for reuse and is supplied in non-sterile condition. Clean and sterilize the device before the first use and any reuse according to the directions given. Warning: Steam for sterilization should be generated from water that has been treated to remove total dissolved solids, filtered to remove contaminants and water droplets, and supplied via piping without deadlegs or other stagnant zones where contamination might collect. Steam saturation should be greater than 97%. Warning: Prior to use, examine the product packaging and the product itself for damage, deterioration, and abuse. If found, do not use the product. Contact Medtronic Navigation.  Precautions Caution: Deviation from the recommended cleaning and sterilization processes is at the risk of the user facility. Caution: Because of the variability in cleaning efficiencies and sterilizer operating parameters, all given parameters (temperature, time, etc.) should be validated by persons who have training and expertise in sterilization processes. Caution: The recommended cleaning and sterilization parameters are only valid with equipment that is properly maintained, calibrated and validated. Caution: Federal law (U.S.A.) restricts this device to sale by or on the order of a physician.  0344  Part Number 9730713, revision 17, 2017-09 Medtronic Navigation Inc, 826 Coal Creek Circle, Louisville, CO 80027 USA
File Type: PDF
File Size: 421 KB
File Name: medtronic - 9730713 - Computer Aided Surgery Systems Equipment Cleaning and Sterilization Instructions - 2017-09 - Rev 17.pdf

By clicking Download you are confirming this is the correct document for your purposes
and that you agree to our Terms & Conditions